How do you install the LCN 9540 Senior Swing (REG) push arm?
Resolution:
When installing the arm; the gearbox shaft and door must be at the (+90°) full open position. The following step are used to install the Sr. Swing (REG) push arm. Install t...:
How do you install the LCN 9530 Senior Swing (STD) pull arm?
Resolution:
When installing the arm; the gearbox shaft and door must be at the (+90°) full open position. The following step are used to install the Senior Swing (STD) pull arm. Install...:
Can you power an electric strike or maglock from the 9500 Series Senior Swing?
Resolution:
An electric strike or maglock (24 volt only) can be wired to a Senior Swing 2800/9500 series operator using the P10 Lock Interface cable.For Current Sr Swing control boxes with ID# 72940 on th...:
When did we start shipping the Senior Swing, Benchmark, and Falcon operators with the ES Filter?
Resolution:
On the Benchmark, if there is line noise from a strike then the unit will lose it's hold open time. Adding the ES Filter, which is a diode, will resolve this issue and the unit will hold it's...:
What is power boost on a Senior Swing or Benchmark operator?
Resolution:
Power Boost is a positive latching feature that increases the latch force, to over come building stack pressure or door weather stripping, etc, if the door stops before co...:
Can a 4040 Pull Side closer be mounted with Swing Clear Hinges?