Allegion
Terms of Use
Privacy Policy
Frequently Asked Questions
Ask your question
Entering your question as a complete sentence will provide more accurate results than keywords or phrases.
User questions
FAQs
Category List
“
lcn senior swing installation
”
RELATED FAQS
Question
Answer
Does the 4600 series operator have a Push N Go feature?
Resolution:
The 4600 Series operator does not have a Push N Go feature. The LCN operators with a Push N Go feature are the Senior Swing, Benchmark, and the Falcon 8200 series.:
How do you order a Senior Swing header for a 2810 on one leaf and a 2010 on the other?
Resolution:
LCN does offer a 2810 Senior Swing / 2010 manual closer combo for a pair of doors. Both units contained within the same Senior Swing header. To order a paired operator with a 2810 o...:
What would cause a Senior Swing to open only 10 degrees and then close?
Resolution:
Issue/Symptom – upon receiving an activation input the Sr Swing gearbox opens only about 10 degrees and then returns to the close position. Unit will never learn opening nor function pro...:
What is the minimum and maximum reveal for a 9500 Series Senior Swing operator?
Resolution:
The 9542, 9553, 9563 surface mounted Senior Swing with a regular arm, mounted on the push side of the door, can handle a reveal from 1 1/8" up to 10". The 9542, 9553, 9563 surface mounted Senior S...:
How do you install the LCN 9540 Senior Swing (REG) push arm?
Resolution:
When installing the arm; the gearbox shaft and door must be at the (+90°) full open position. The following step are used to install the Sr. Swing (REG) push arm. Install t...:
How do you install the LCN 9530 Senior Swing (STD) pull arm?
Resolution:
When installing the arm; the gearbox shaft and door must be at the (+90°) full open position. The following step are used to install the Senior Swing (STD) pull arm. Install...:
Can you power an electric strike or maglock from the 9500 Series Senior Swing?
Resolution:
An electric strike or maglock (24 volt only) can be wired to a Senior Swing 2800/9500 series operator using the P10 Lock Interface cable.For Current Sr Swing control boxes with ID# 72940 on th...:
How do you install a Senior Swing 9540 on one leaf of a double door?
Resolution:
Surface Mounting - A 9542 HDR2 (Double Door Header) and a 9540-18 mounting plate can be used on the active leaf. A manual closer with a PA (parallel arm) can then be installed on the inactive leaf....:
What LCN operator would be equal to Horton 4000 series operator?
Resolution:
The Senior Swing series operator would be the LCN equivalent to the Horton 4000 series operator.: