The 62A shoe is used when it is necessary to install the door closer (lower) down on the door so that it will operate under accessories such as overhead stops, coordinators, etc.
The Senior Swing operator is designed to power open the door to 90°. The built in dead stop (in the gearbox) prevents it from opening any further. If the Senior Swing operator is opening to far (pa...
The LCN Safety (Finger) Guard was a heavy duty vinyl product that covered the opening between the door and frame, where most hand injuries occur. The LCN 750 Safety (Finger) Guard was the pul...
The 3130 Series closer is UL listed- Fire Rated (UL-10C) for up to 3 Hr.The Door and Frame Manufacturer needs to be contacted to verify their Door/Frame rating would not be compromised wh...
 Cam Lift Hinges are specially designed hinges used mainly on acoustical door assemblies. The Cam Lift Hinge lifts the door during its travel and seats the door bottom for a pos...
The old 4030 series was: Handed Mounted regular arm hinge side. Had sized springs, were not adjustable. The 4033 is an obsolete closer.  If required, handing can be verified by looking at ...
Clear Opening Width for swinging doors is measured (with the door open 90 degree) from the face of door to stop soffit on strike jamb.          &nbs...
Here is an updated list of errors shown on keypad display of the Senior Swing control: Er04 - Voltage Monitor was high during Opening hardware check. Er05 - Master or slave CPU has oscillator ...
EDA ARM - The EDA arm is a heavy duty parallel arm mount.  The degree of door opening is determined by the template used for mounting. EDA arm closers can only be mounted as a Push Side parallel ar...
LCN "does not" recommend the use of SRT screws is wood doors. LCN "only" recommends the use of Wood Screws in wood doors and frames, as noted on the installation instructions.
Use the PS902-2RS power supply with LCN auto operator on single door, PS904-2RS power supply on double door and PS904/906-2RS-2RS for 2 pair of QELA is required for basic operation with a...
LCN does not does not have or supply any information for the old (obsolete) "High Energy" Dor-O-Matic Sliding doors, Bi-Fold doors or Astro Swing doors. You MUST be AAADM certified to work on, or g...
SRT "Self Reaming, & Tapping" screws are the default type screws shipped with LCN closers, when a specific screw type is not specified.   There are 3 standard lengths of SRT screws: 1-3/8" 1...
There are a few things that can cause a closer to slam. The closer could be adjusted incorrectly. Turn all regulating screws clockwise until they stop. Then open each valve 1 and 1/2 turns. If t...
Make sure that the hold open nut is not on upside down.  The orientation of the hold open nut depends on the mounting. On a Top Jamb "Push Side" mount, the hold open nut would poi...
It would be unnecessary to use the CNS/Cush arm and the Glynn Johnson overhead devices in the same application, both mechanisms stop the door.
STANDARD ROD AND SHOE: 4020, 4031, 1460, 1520, 1370, 1070, 1260, 4640, 4820 is: 8 3/8” LONG ROD AND SHOE: 4020: 4031, 1460, 1520, 1370, 1070, 1260, 4640, 4820 is: 12 3/8” STANDARD ROD AND SHOE: ...
A 1460 Pull Side can be mounted standard template for 180°, frame and trim permitting.
A 4030 Pull Side can be mounted standard template for 180°, frame and trim permitting. 
A 1260 Pull Side can be mounted standard template for 180°, frame and trim permitting.
LCN does not offer any products for sliding doors.
If a door is being held open by the LCN SEM 7800/1900 magnet or any ME/SE Series Sentronic LCN closer, you can remotely release that door to close by ordering the following parts and wiring per ST ...
All LCN closers have UL listings, and are Fire Rated for up to 3 hours.
Regular LCN closers have "3" regulating valves for General Speed, Latch Speed, and Backcheck. If the LCN closer has "4" regulating valves, then the closer has the Delayed Action feature. De...
Hold Open Closers & Magnets (Fire/Life safety products) provide a wide range of solutions.  Single or multi-point hold open closers Utilize an electromechanical closer. Hold the door o...
Because of the new extended LCN warranties and the desire to be consistent across the entire Allegion premium brands, LCN will be moving away from offering an out-of-warranty repair service beginni...
The capabilities of the auto operator and the required operation of the opening will affect the selection of a power supply.
The 900-4RL has two out put for EL devices and signals to the auto operators to open the doors. PS914 power supply is required with 900-4RL option board to operate the EL device and auto operato...
Von Duprin PS914 x 900-4RL supports two EL with two auto operator.
The LCN closer fluid "Liquid X" will perform without variation between:  -30° F to +120° F - for manual closers.  +35° F to +120° F - for electrical closers and automatic operators. At around ...
How to:  What are the steps to adjust a door closer?Facts: All LCN and FALCON door closers will have 3 regulating valves and a spring adjustment.  All closers with a "Delay" feature ...
Try the steps below to improve the hold open adjustment. Remove hold open nut  Apply a couple drops of blue loctite to the threads. Re-assemble, and reset hold open. Let loctite set up overn...
The fluid in an LCN closer must not be refilled in the field. See attached Warranty and Repair Communication 
The 4000T Series closers have a maximum opening of 90°.
Any LCN Closer that ends in the number 1, will meet ADA 5 lbs opening forces.
Neither Dor-O-Matic or LCN manufacturers a floor closer. 
LCN does not supply Allen wrenches, the size that LCN uses, are standard sizes that every installer will have in their tool kit. 3/32" Allen wrench for adjusting regulation valves: main speed, lat...
For a door closer that tries to open the door instead of closing it:The closer body could be mounted backwards on the door - check instructions for proper closer orientation.It could be the wrong h...
The programming processes for Allegion devices can be both product and features specific.  Some products programming processes are electronic in nature, others are physical in nature. &nbs...
The standard 1460 EDA arm is not long enough to allow the door to open 180°.
The maximum recommended door weight for LCN closers is 225 lbs.
Cam Lift hinges can only be used with LCN door closers that have a "Regular" style arm.     Manual Closers: Maximum lift dimension is 3/4". Can not be use EDA, CUSH, or Track Arm door closers...
Yes, as long as you stay with the like style arm.  Example: replace an RW/PA with HW/PA, replace an EDA with HEDA, or replace a CUSH with HCUSH.
Special Rust Inhibitor (SRI) - is a pretreatment that is applied to the metal components prior to the addition of the LCN powder coat finish, standard or custom. ...
The old 4030/4130 closers and arms are obsolete, there is nothing to replace them. No arm from other closers will fit  There is no closer that can replace the old 4030 series closer with the exa...
The hold open position on a "REG" or "EDA"  hold open arm is set with the door to a few degrees shy of the desired hold open point. To properly set, open the door 5° less then the desired hold open...
Electro-hydraulic Automatic Operators are: Designed for manual opening applications where there is occasional need for automating the door to meet ADA requirements.  Electrically powere...
First, turn off the power to the Senior Swing. If the door closes, check controller for a constant activation signal from an activation device. If door continues to hang up and will not close...
The regulation valves are designed to adjust the flow the hydraulic fluid in the closer which regulates the door closing speed through various phases of the closing cycle. The regulation valves h...
Chexit devices are NOT electric latch retraction.  In order for Chexit device to operate with an auto operator you will need to add a rim electric strike on a single door or a pair o...
The 1260, 1460, and 4030 regular arm closers on the pullside will allow 180° door opening and can be held open at 180°, frame and trim permitting.
Surface Mounted door closers are the most durable and common type of door closer. Mounted to the surface of the door or frame Can be configured (through installation or arm type) to meet a...
The minimum clear opening width for ADA is 32" measured from face of door opened to 90 degrees to face of stop on strike jamb. There must be no hardware mounted to the door projectin...
ElectroMechanical Automatic Operators are designed to automatically open when activated. The Benchmark Series are Medium Duty "Commercial" automatic operators, often used on of...
ST Number Product 1 Product 2 Description ST-2776 4040XP Rw/62A Overhead stop 81, 90, 100, 410, 450 series The standard P...
 Pneumatic Automatic Operators are used in areas where electrically operated devices are not convenient or permitted.  Consists of a modified, heavy-duty door closer for manual oper...
The "320G" is the # on a UL sticker attached to the arm of most LCN door closers, and is not a door closer model number.  The "320G" means that the arm is not a mechanical hold open device and OK t...