Answer
What is the part number for a hex dogging shaft for Falcon Dor-o-Matic 1690 or 1790 exit device?
Resolution:
The part number for 1690/1790 hex dogging shaft is shaft.101:
Does Von Duprin offer an NL or NL-OP function with the 8827 exit device?
Resolution:
This option is not available as there is no NL cam to directly drive the rods and using a key to lift the heavy stainless, brass or bronze rods would damage the key. :
Is the Falcon 1390 exit device dogging kit (4270106669) still available?
Resolution:
The Falcon 1390 exit device is discontinued and parts are no longer available from the factory. New England Door Closer may still have some older kits and can be contact...:
What trim will work with the discontinued Monarch18 series exit devices?
Resolution:
Falcon Monarch XX series trims will work with Monarch 18 series exit devices.:
What cylinder is used in a 210K trim for the 22 series exit device?
Resolution:
Equivalent to the Schlage D series line with a C keyway. Part number 21-002.:
What is the part number for the pcb board on the 2670 Guard X exit device?
Resolution:
The following are part numbers for 2670 Guard X exit device PCB: pcb.10018 for English pcb.10019 for Spanish pcb.10020 for French:
Are factory finished doors and frames available from Steelcraft?
Resolution:
Factory finished painted doors are available from Steelcraft. Frames "are not available" factory finished from the factory.Doors are offered in variety of standard colors or can be finish...:
I have an old PL series padlock what is the KS replacement?
Resolution:
:
What is the length of a cylindrical tailpiece?
Resolution:
Key-in-lever tailpieces differ in length depending on the lock series, function, and design. Click here to identify the tailpiece and length. NOTE: Modular ...:
DEVICE LENGTHS
Resolution:
36", 48", Special length:
Is there a chart that shows which sex bolts are required for mounting the Von Duprin and Falcon/Monarch exit devices?
Resolution:
There is not a chart that shows which sex bolts are required for Von Duprin or Falcon/Monarch exit devices.:
How do you install the LCN 9540 Senior Swing (REG) push arm?
Resolution:
When installing the arm; the gearbox shaft and door must be at the (+90°) full open position. The following step are used to install the Sr. Swing (REG) push arm. Install t...:
What are the wire gauge and length requirements for QEL devices?
Resolution:
Use #18 gauge wire up to 200 feet maximum distance from PS900 x 900-2Q power supply to the QEL exit device. The new QEL+ no longer requires the 900-2Q board but still needs a different option board...:
Is there an identification chart for all the different rollers that LCN has?
Resolution:
On Feb 8th, 2016 - LCN launched the redesign of the Hold open clip which changed multiple components of our Track style closers, including the roller, track, hold open clip, and bumper. :
How do I manually change PIN length on an AD200?
Resolution:
Beginning with Firmware Packages ADFwPkg 2.16.3 and COFwPkg 1.20.0 the PIN length can be manually changed for AD200 and CO200 locks as follows: 1. Press {programming code (default is 97531)} then ...:
Will the Falcon 24 R with deadlocking accept the LM/DM switches?
Resolution:
This configuration is not possible as the anti-pick plate of a "DL" or "F" device center case interferes with the LM/DM switch mounted also on the center case. :
What back plate conversion kit is required for the 88 with the 373L trim?
Resolution:
Attached tables provide the back plate conversion kit for all 88 series Exit devices. 88 Back plate conversion Chart :
What would keep the vertical rod exit devices top latch from being held retracted in the open position?
Resolution:
Following exit devices 2227/F, 33/3527A/F, 33/3547A/48A/F, 98/9927/F and 98/9947/48/F have similar rod adjustment procedures. All top latches control the bottom latch assemblies. When do...:
What would cause the Von Duprin 88 series exit device latchbolt not to extend and the crossbar to droop?
Resolution:
The spring in the hinge case or end case assembly lifts the crossbar and both lever arms. If broken, the crossbar and lever arms will drop down. The weight of the crossbar and levers will automati...:
Can the CD cylinder dogging and RX switch be ordered with 33/35 or 98/99 exit device?
Resolution:
This can be done ONLY with non fire rated exit devices.:
Will the new Von Duprin 33A/35A center case work on old 33/35 series exit devices?
Resolution:
The new 33A/35A center case will not work with the old 33/35 series exit devices. It is never intended to use parts to convert a device from one Series to another Series as this w...:
Do we offer a lever trim with squared top and bottom for the 98/99 series exit devices?
Resolution:
The Von Duprin 994L series trims were square on top and bottom. They were discontinued in July 2010.:
What cylinder is needed with Von Duprin exit alarm ALK?
Resolution:
The ALK uses a 1 1/4" mortise cylinder with straight cam. (NO DOGGING):
How do you specify an exit alarm ALK with a hard wire to the power supply?
Resolution:
All new 22, 33/35A and 98/99 series exit devices with exit alarm ALK option can be hard wired to the PS902 power supply as a standard feature.:
How does the Von Duprin 98/99 rim or vertical rod exit device with lever trim convert from L to L-NL function?
Resolution:
To convert the Von Duprin 98/99 Rim or Vertical (Rod or Cable) Exit Device with functional lever (996L-R/V) to act like a rigid lever (996L-NL-R/V) with key over ride follow these steps: R...:
Where do I install my Auxiliary Fire Latch (AFL) in a Less Bottom Rod, Fire Rated (LBR-F) exit device?
Resolution:
Installation should be 6" from bottom of the door. See attached templates as reference. T-5494 for HM Doors W-5494 for Wood Doors:
Can the Falcon Monarch 718C or 718NL trim be used with the 25-C exit device?
Resolution:
The Falcon Monarch 718C and the 718NL trims can be used on the 25-C exit device. The 718C trim is listed in the Price Book for the 25 series The instructions attache...:
Is the Von Duprin 6111 electric strike compatible with Von Duprin XP98/99 rim exit device?
Resolution:
This is not a recommended application as the electric strike does not have the same holding force as the XP98/99 rim exit device. Typically the XP device will withstand a higher force than electr...:
What is the difference between LR and PL latches on Von Duprin 8827 exit devices?
Resolution:
ES (electric strike) latch is only used with the 8827 less bottom rod on a non fire rated exit device with a 6111 electric strike.:
Does the Von Duprin 6121 electric strike work with the Von Duprin XP exit device?
Resolution:
Von Duprin does not recommend using XP98/99 devices with any electric strike. Von Duprin recommends using the standard 98/99 rim device. :
Can the CD and EL options be provided on the same 98/99 rim or vertical rod exit device?
Resolution:
There is not enough room for both Cylinder Dogging (CD) and Electric Latch Retraction (EL or QEL) options because they both try to occupy the same space in the device.The dogging mechanism for cyli...:
What is the device backset when using a 1790 with a 6111 strike?
Resolution:
The Von Duprin 6111 electric strike would work with DOM 1790 device on medium style doors Centerline of the 1790 device mounting screws are located 1 11/16" from face of stop. See d...:
What parts of the device and trim for the 98/99 are 643E finish?
Resolution:
Device: Pushbar end caps, pushbar trim and center case cover. Trim: Lever assembly, trim plate assembly (trim plate and bushing sleeve).Bronze Finish Comparison:
Is there a fire rated version of the 33A/35A rim device?
Resolution:
There is not a fire rated version of the Von Duprin 33A/35A rim device. Only the vertical rod devices (33/3527A-F, 33/3547A-F, 33/3548A-F) can be fire rated.:
How do I change the function of the Von Duprin 7500 mortise lock from Lever ( classroom ) to NL ( night latch )?
Resolution:
To convert the Von Duprin 9975L to 9975NL exit function follow these steps (Note: the mortise lock is shipped as Night Latch from the factory): Turn the NL screw on 7500 mortise lock counter clo...:
How do you mount a 55 rim with the 379 where the studs do not line up with the mounting screws?
Resolution:
Position the 379L trim and attach with countersunk screw into the bottom stud of the trim. Position the 55 Rim device and attach with the device mounting screw through the he...: