Allegion
Terms of Use
Privacy Policy
Frequently Asked Questions
Ask your question
Entering your question as a complete sentence will provide more accurate results than keywords or phrases.
User questions
FAQs
Category List
“
Is RX available for D series
”
RELATED FAQS
Question
Answer
Does the Von Duprin ALK require the RX switch to operate?
Resolution:
The RX switch is required to activate the ALK. The RX switch monitors the pushbar and will signal the ALK to go into alarm when the pushbar is depressed. The RX switch also allows free in...:
What is the difference between Von Duprin LX and/or RX switches and the Signal Switch SS option?
Resolution:
The RX monitors the push bar while the LX monitors the latch bolt of the exit device. A SS device has an LX and a key cylinder switch plus an emergency push bar signage.:
What is the wire gauge on the motor driven L9000 mortise locks?
Resolution:
Supply wires - 24AWGRX wires - 20AWGLX wires - 20 AWG:
When did we Von Duprin release the RX996L trim as a standard?
Resolution:
The Von Duprin RX996L trim was released to standard order entry in May 2010. The Von Duprin 996L and 996L-BE trims can be ordered with RX switch. The 996L-NL and 996L-DT trims can not have the...:
What power supply is used with RX or LX switches?
Resolution:
The RX switch is request exit and the LX switch is latch bolt monitor switch. They do not require a power supply directly. The electrified hardware that the RX or LX switch...:
When was the Falcon W Series launched?
Resolution:
The Falcon W-Series was launched in April of 2006.:
What is the 4310HSA/4410HSA series closer?
Resolution:
HSA - stands for Holder Scanner Activation.The HSA is an electrically controlled closer/holder designed to provide easy passage for groups of pedestrians through high traffic doors. With a constant...:
Does Schlage or Falcon manufacture a stainless steel cylindrical or mortise lock?
Resolution:
Schlage does not have a stainless steel/non-ferrous lock series. The only option that Allegion provides is the Grade 1 cylindrical Falcon X-Series. To order the Falcon X with the stainless st...:
Can we still supply the 812 L trim for the Monarch 18?
Resolution:
Allegion stopped manufacturing he 812L trims when the Falcon/Monarch XX Series crossbar devices were discontinued in 2019.The 812L trims had also been used on the Monarch 18 Series pushpad devices ...:
When was the BC100 series of deadbolts discontinued?
Resolution:
The BC100 series product line was discontinued on 9/14/2007 and replaced by the B500 series.:
Can you get Avalon lever for 25 series lever trim?
Resolution:
See 24 and 25 series trim section in the Price Book.:
Does the SL-Series door have a square edge?
Resolution:
The SL-Series door is a square edge non-handed door. A Hinge Filler (also referred to as Hinge Spacer) is the small removable trim part located on the door between hinge leaf and hinge reinforcem...:
Can you use a CD conversion kit on a 22 device?
Resolution:
Cylinder dogging CD is not available with 22 series exit device.:
What does AVB mean in a closer and which closers are available with this option?
Resolution:
AVB stands for Advanced Variable Backcheck. It is a cylinder option when ordering a 4111 closer (without an ST) that allows backcheck to start at about 45 degrees instead of the normal 75 degrees.T...:
Does the ND lock have an RX option?
Resolution:
The ND lock is available with an RX option: When ordering a complete ND lock specify RX when the request to exit (RX) switch is required. The ND80EL, ND80EU, ND96EL, ND96EU, ND12EL, ND12E...:
Is the RX option the same as the old AE option on Falcon exits?
Resolution:
The AE option is now called RX (Request to Exit) to match other Allegion exit brands nomenclature. The feature of getting a signal from the pushing of the device's pushpad is the same. :
Why does the AD300-993 and AD400-993 require Von Duprin RX-LC switch
Resolution:
Here is detailed information on why the Von Duprin RX-LC Swtich is required by the AD300 and AD400 993 units. A low current switch is needed because … - &nb...:
Does a Von Duprin ALK kit come with an RX switch?
Resolution:
ALK kit comes with standard RX switch. It can be ordered without the RX switch or with LX switch as an option.:
What is the L9080 by L283-263?
Resolution:
L283-263 and L283-239 are obsolete part numbers that were used to specify "request to exit" on the L9000 and LV9000 locks. To specify RX on L9000 locks after January 2, 2017, specify the lette...:
Falcon MA lock wire color.
Resolution:
Solenoid: Black (2 wires) RX (monitors both sides) Normally Open: Green (pin 6 when connector included) Common: Orange (pin 5 when connector included) The current version o...:
Will Von Duprin supply the 996L, 996L-BE, 996L-NL and 996L-DT trims with an RX switch?
Resolution:
Von duprin will supply the 996L and 996L-BE trims with RX switch. Von Duprin will not supply the 996L-NL and 996L-DT trims with RX switch because the switch monitors the lever movement and the leve...:
Is there a template that shows where to drill the hole for E/EL/SS/RX/LX/CX wires?
Resolution:
The hole should be drilled in the field once the end cap is located on the door. It is a 5/8" hole, that is located 5/16" from the end of the mechanism case. See installation instruction of t...:
What are the Von Duprin part numbers for RX, LX and RX,LX-LC switch kits for field installation?
Resolution:
The attached table shows the part numbers for LX-RX and LX-RX-LC switches field installed.:
Who can adjust or replace the Chexit RX switch?
Resolution:
For Chexit devices with solenoid driven shipped from the factory prior to 8-24-2015, the RX switch is ordered as a "Special CX RX Switch". It may only be installed or adjusted ...:
What are the 3 wires on the Falcon AE switch?
Resolution:
For 24/25 devices per instructions : Violet - Normally Open Black - Common Gray - Normally Closed:
Explain the ND80 function.
Resolution:
The 80 (Storeroom function) operates as follows: Key retracts latch (entrance by key only):
Can a pneumatic (PN) 33A/35A/98/99 exit device use the RX or LX switches?
Resolution:
PN33/35/98/99 Pneumatic exit devices are not usually used with RX or LX switches since the Pneumatic PN device is used instead EL to eliminate the electric from the device.:
What type of switch is used for the RX and latch monitoring options for the ND and L locks?
Resolution:
The ND-Series RX, the L-Series RX and latch monitoring switches are Form C - Single Pole Double Throw (also known as SPDT).:
Can the Von Duprin RX Switch be installed on an existing Falcon Monarch 19?
Resolution:
The devices baseplates/scissor assemblies are different and will not accept the Von Duprin RX switch.:
What finishes should be used on exit devices near the ocean or in saltwater environments?
Resolution:
Von Duprin Exit Devices (33A/35A, 98/99, etc) are handled on a case by case basis regarding their ability to handle salt and chemical environments. Our powder coated finishes US28 (Anodized Alum...:
Is the AD CO with a 993 chassis compatible with the Von Duprin 33A exit device?
Resolution:
No, the 33A is not compatible with the AD and CO 993 chassis units. The 33A can only be driven in a clockwise direction. This would restrict it to right hand installs only.:
What is the XL12-246 or XL12-245 option?
Resolution:
:
ND80-RX
Resolution:
Storeroom Lock with Request to Exit - The Outside Lever is same as ND80 - The Inside Lever is the same as ND80- A microswitch attached to the chassis is activated when the lever is rotated. The sw...:
ND12EU-RX
Resolution:
Exit Lock— Electrically Unlocked (Fail Secure) with Request to Exit - The Outside Lever is the same as the ND12EU - The Inside Lever is the same ND12EU. and a micro switch attached to the chassis i...:
ND12-RX
Resolution:
Exit Lock-with Request to Exit - The Outside Lever is same as ND12 - The Inside Lever is the same as ND12 - A microswitch attached to the chassis is activated when the lever is rotated. The switch ...:
What replaces the Von Duprin PS873 power supply?
Resolution:
Option Board Von Duprin PS914 Schlage PS902, PS904, PS906 900-2RS Yes No 900-2Q ...:
Do we make a blank trim plate to replace an existing trim?
Resolution:
We have several blank trims listed in the price book to cover existing trim prep in door. DEVICE EO TRIM 22 230EO 88 880EO 98/99 990EO or 996EO* 33A/35A Rim, 33/3...:
Where is the template for the 718 trims made after 2/28/2011 for Falcon/Monarch concealed vertical rod devices?
Resolution:
Templates for current 718 series trim can also be found on Falcon website:
Can you use a Senior Swing controller as a replacement for an obsolete Mid Swing controller?
Resolution:
The Mid Swing was discontinued Sept. of 2009. The Sr. Swing control box has the power boost feature which the Mid Swing control box did not have. If you replace only the Mid Swing control box...:
Can the EL solenoid be replaced in the former Monarch 17/18 devices?
Resolution:
It can but the solenoid will need to be purchased through New England Door Closer as the factory discontinued the old ELR solenoid (part #650092-000) in June 2010.:
Does Falcon offer a Delayed Egress exit device?
Resolution:
There is not a fully self-contained delayed egress like a Von Duprin Chex-It device but the Falcon RX-24 or RX-25 Series can perform a delayed egress by using the DE5300 controller, power supp...:
Is there a flat lip option for the ND series?
Resolution:
There are two flat lip strike options: Specify XQ02-309 for a 10-013 strike - specify 7/8" Specify XQ07-351 for a 10-025 strike - specify 7/8" :
Do Steelcraft PW-Series doors and FP-Series frames meet FEMA Tornado Resistant requirements?
Resolution:
Steelcraft Paladin PW-Series doors and FP-Series frames meet FEMA Tornado Resistant requirements and have been designed and tested to meet the requirements of FEMA 361 guidelines and ANSI ICC 500...:
Does the Falcon T series have an RX option available?
Resolution:
The Falcon T Series lock does not have an RX switch available.:
Can a 55 or 88 series device have a request to exit switch?
Resolution:
The Request for Exit (RX) is available on the 55 and 88 Series Von Duprin devices.The RX switch is installed in the end case of 55 and 88 series exit devices.There is no kit to field install the RX...:
Do we offer a RX switch for the 17 or 18 device?
Resolution:
This option is not available. The 17 & 18 Series devices were discontinued in August 2009 and the new Falcon RX Switch is mounted to a bracket that fits in the pushpad...:
Can the 94/9547 have the RX option?
Resolution:
The RX request exit switch is not available with 94/95 exit devices.:
Is the RX available for the Von Duprin 330 dummy bar?
Resolution:
The 330 must be ordered as a RX330 to have the RX switch. You can NOT add a RX to an existing dummy 330 bar.:
Is the MA lock available with the RX feature?
Resolution:
The MA RX features a single switch within the chassis that will monitor both the inside and outside knob/lever. The switch is only available as Normally Open (NO).:
Can you field install a RX switch on the 24/25 device?
Resolution:
The RX switch can be installed at the factory when device is ordered or in the field with part# 650359-00. Installation instructions here will show how the RX swi...:
How to test the RX switch in a Chexit device.
Resolution:
Chexit devices shipped prior to 8-24-2015 with solenoid driven: If Chexit device goes into alarm with fast flashing red LED after the rearm time, the RX switch may be out of adjustment or defect...:
Can QEL and RX be added to an existing 9927?
Resolution:
The QEL conversion kit (3' or 4') and the RX switch kit (050251-00) can convert the 9927 to QEL-RX9927 device.:
What is the part number for the CX-RX switch?
Resolution:
For solenoid driven Chexit devices shipped from the factory prior to 8-24-2015, the RX switch is no longer available. This part was discontinued in 2019. If the older version Chexit RX s...:
What is the difference between an RX switch and an RX-LC (low current) switch?
Resolution:
The standard Von Duprin switches (RX and LX switches in exit devices, and DS dual switches in 6100 and 6200 Electric Strikes) are rated for 0.05A to 2A @ 24 VDC. The low curren...:
What degree of lever rotation is required to operate the RX feature?
Resolution:
The RX switch is activated at approximately 18 degrees of lever rotation. :
Can you add the LX option to a Von Duprin device that already has the RX option?
Resolution:
The Von Duprin RXLX combination switch must be ordered together as one assembly. Existing RX or LX switch must be removed to install the combination RX LX switch. Make sure correct RX LX combinatio...:
What is (SD) Special Dogging?
Resolution:
SD is Special cylinder dogging in the center case of 98/99 rim and vertical rod non fire rated devices and is available with standard, EL, QEL, CX and ALK.:
Can you put an EL on a Von Duprin 22 device?
Resolution:
Von Duprin 22 series are not available with electric latch retraction EL option. 22 series are the economy device and are only available with RX, LX and exit alarm ALK. EL option is only availa...:
Can the CD cylinder dogging and RX switch be ordered with 33/35 or 98/99 exit device?
Resolution:
This can be done ONLY with non fire rated exit devices.:
Can you have a RX and CX in the same device?
Resolution:
The CX device has an internal RX switch that is wired to the CX circuit board. This RX switch is not available to outside monitoring and no other RX switches may be added to the CX device. :
What is the part number for the lever return spring for the old M series mortise lock?
Resolution:
Falcon is reintroducing the lever return spring for the discontinued Falcon M mortise series. Effective November 1, 2014 the lever return spring is now available for purchase with a list pric...:
What is the part number for the 88 series dogging screw?
Resolution:
The part number for 88 series dogging screw is 090004 (package of two) and 090083(package of ten).:
Why can't I LINK my AD-Series lock?
Resolution:
4. PIM400/AD400 COM400 plug could be damaged! The small pins in the Main PCB board connection for the RF COMM board can get bent during installation of the RF COM400 board. If the PINs are be...:
Is the Falcon Y lock discontinued?
Resolution:
Falcon strives to provide a solid product, with solid performance, at a solid price. To better align with this mission statement the Grade 2 tubular Falcon Y lock and all parts will be...:
What power supply replaces the PS 873 - 4TD?
Resolution:
Option Board Von Duprin PS914 Schlage PS902, PS904, PS906 900-2RS Yes No 900-2Q ...:
New FSIC driver info for the AL locks.
Resolution:
The new AL FSIC driver part number is A700-052. This driver snaps onto the back of the core similar to the ND, as opposed to it being assembled into the lock chassis with a retaining ring. Th...:
What hinges can be used on tornado doors?
Resolution:
The following hinges are available on Paladin series doors and frames: Butt hinges - 4 1/2" or 5" ball bearing type either standard or heavy duty Continuous hinges - full ...: