How to test the RX switch in a Chexit device.

Chexit devices shipped after 8-24-2015 with motor driven:
If two pin REX connector cable is plugged into the Chexit module and Module REX LED is OFF, the RX switch is defective and needs to be replaced. This switch can be replaced by qualified installer.


Chexit devices shipped prior to 8-24-2015 with solenoid driven:
If Chexit device goes into alarm with fast flashing red LED after the rearm time, the RX switch may be out of adjustment or defective. By pass the RX switch by shorting the two orange wires together near the plug connector. If device arms properly contact your sales office to locate an authorized representative to replace or adjust the Chexit RX switch assembly.