Allegion
Terms of Use
Privacy Policy
Frequently Asked Questions
Ask your question
Entering your question as a complete sentence will provide more accurate results than keywords or phrases.
User questions
FAQs
Category List
“
glynn johnson concealed
”
RELATED FAQS
Question
Answer
Will the new concealed vertical cable system work with any door height?
Resolution:
:
What are Electro-hydraulic Automatic Operators?
Resolution:
Electro-hydraulic Automatic Operators are: Designed for manual opening applications where there is occasional need for automating the door to meet ADA requirements. Electrically powere...:
What are Hold Open Closers & Magnets?
Resolution:
Hold Open Closers & Magnets (Fire/Life safety products) provide a wide range of solutions. Single or multi-point hold open closers Utilize an electromechanical closer. Hold the door o...:
FIRE RATED CONCEALED VERTICAL ROD FIRE DEVICE
Resolution:
9847-F Series ,9947-F Series, 98/9947WDC-F, 5547-F, 5547WDC-F, 8847-F:
How do you identify what size a 2030 closer is?
Resolution:
The Date Code and Closer Size are stamped in the backside of the closer body. These stamps will be on a smooth machined surface of the cylinder.Closer Size:If the number is "1", the...:
Will a 510L or 511L trim work for a vertical, mortise, concealed, or rim device when ordering the trim by itself?
Resolution:
The "500" Series trim in general (510L, 511L, 512's, & 513K) will work with all 25 series devices and are not device specific.:
Is there a retrofit closer available for the obsolete 303 OHC closer?
Resolution:
The LCN direct retrofit for the Obsolete 303 OHC closer was the 330 series, it was discontinued in 2009. The 3030 closer door closer body can be used as a replacement cylinder. :
Is the Von Duprin 1609 strike fire rated for pairs of doors?
Resolution:
The Von Duprin 1609 cannot be used on a pair of fire rated doors. We recommend using the Von Duprin fire rated mortise exit device in lieu of the rim device such as the Von Duprin 5575-F,...:
What are ElectroMechanical Automatic Operators?
Resolution:
ElectroMechanical Automatic Operators are designed to automatically open when activated. The Benchmark Series are Medium Duty "Commercial" automatic operators, often used on of...:
Can Steelcraft doors be prepped for the 98/9949 Concealed Vertical Cable Exit Device?
Resolution:
Yes, as an option, Steelcraft doors are available with factory prepared for the 98/9949 Concealed Vertical Cable Exit Device.L, B, CE, T and CE-Series doors are available factory preparedDoor prepa...:
What is the difference between Von Duprin 98/9947 and 98/9948 concealed vertical rod devices?
Resolution:
They both use Template # 10320_c:
Are there any parts available for the old Dor-O-Matic 1200 overhead concealed series closers?
Resolution:
The Dor-O-Matic overhead concealed manual door closers have been obsolete since 1999, and there are no parts available for them.:
Can I use a Glynn Johnson 410 with a 4040 regular (pull side) mount?
Resolution:
ST-1630 is required when mounting a 4041 or 4040XP door closer regular (pull/hinge) side with a concealed GJ100 or GJ410 series over head stop.This ST also REQUIRES the use of a 4040-18TJ drop plat...:
What are Overhead Concealed door closer?
Resolution:
Overhead Concealed door closers are used to provide a more aesthetic look to the opening. Concealed in either the frame or the door Offer the ability to be adjusted to maintain...:
Can I use an AD or CO - 993 Exit Trim with a Von Duprin 98/99 Concealed Vertical Rod exit device on a wood door?
Resolution:
The AD or CO - 993 is NOT compatible with a Von Duprin 98/99 Concealed Vertical Rod exit device on wood doors.:
What is the difference between the 2030 and 5030 closer?
Resolution:
2030 and 5030 are both overhead concealed closers. Catalog information can be found here. The 2030 uses a concealed, in the door, track, and a concealed one piece arm. The 5030 use...:
What are Pneumatic Automatic Operators?
Resolution:
Pneumatic Automatic Operators are used in areas where electrically operated devices are not convenient or permitted. Consists of a modified, heavy-duty door closer for manual oper...:
Can a 4040 regular mount installed on the pull side and a Glynn Johnson 90 be mounted together?
Resolution:
The LCN 4041/4040XP and the Glynn Johnson 90 series can be mounted in conjunction with each other without a special template. The 4040 door closer is on the pull side of the door and the GJ 90 is ...:
Can a Glynn Johnson 90 stop be used with a top jamb mounted 4040?
Resolution:
A 4040-18G drop plate will be needed to drop the closer and arm down far enough not to conflict with the GJ 90 series overhead stop.:
What special template (ST) is used with a 4110 closer and GJ90 series?
Resolution:
ST-2730 is used with a 4110EDA closer and GJ901-904 overhead stop.This can only be used with GJ901-904.If a drop plate is required, a 4010-18 drop plate would be used (A 4110-18 drop plate can not ...:
How is the 100 series from Glynn Johnson different from the 100 ADJ series?
Resolution:
The basic units are similar. The ADJ has a 12" long track that is mounted in the frame to allow the degree of opening to be selected in the field anywhere from 85 to 110 degrees, where the standar...:
What special template (ST) is used with a 4040(XP) Rw/PA mount closer and a GJ overhead stop?
Resolution:
The use of a 62A Shoe (required) would be used to mount a 4040XP Parallel Arm with a "SURFACE" GJ 70, 79, 81, 90, or 450 series stop. You would order the 4040XP with a Reg w/62A arm op...:
CONCEALED VERTICAL ROD
Resolution:
CV:
Can I mount an LCN Cush closer with an GJ overhead stop?
Resolution:
It would be unnecessary to use the CNS/Cush arm and the Glynn Johnson overhead devices in the same application, both mechanisms stop the door.:
Where are hardware templates?
Resolution:
All the templates can be found at us.allegion.com Please click here :
Will a GJ 90 overhead stop work with an LCN 4642?
Resolution:
The LCN 4642 operator can be used with a GJ90 series stop, but you will need to follow the Flush Ceiling Template for installing the 4642.:
What special template (ST) is used with a 2030 closer and GJ over head stop?
Resolution:
Special template ST-2211 is used to mount a 2030 series closer with a GJ 70,79,81,90, and 450 series overhead stops. This ST works with any GJ "surface" mounted stop. The 2030 closer cannot b...:
Can you convert a Glynn Johnson 100 series holder or stop to an ADJ version? Or can you convert a 100 series ADJ to a standard holder or stop?
Resolution:
No, the door and frame preparation are different, and the arms and tracks are different on the standard versus ADJ products. A new unit must be ordered if you want to change the function to o...:
What is the function of an SE version of Glynn-Johnson overhead stop series 90, 100, 410, or 450?
Resolution:
The SE is a special Stop Only function available with certain overhead stops (90, 100, 410, 450 series). The SE stop should only be used with single-point hold-open electronic closers such ...:
What closer can be used with Soss invisible hinges?
Resolution:
Using Soss hinges with closers can require special device and preparation locations. If you have questions on specific closer applications, please e-mail your request (including a description ...:
Can I use a 4040 EDA and a Glynn Johnson 100 series concealed stop together?
Resolution:
There is not a conflict between the 4041/4040XP EDA door closer and the GJ 100 or 410 overhead concealed series stops. The exception is: the 4041/4040XP mounted on a drop plate, and the Glynn Jo...:
What is the Ives invisible latch replacement for the Glynn Johnson AA, BB and AP2 latches?
Resolution:
The Ives version is the same as old Glynn-Johnson versions.:
Can a 4110 EDA and a Glynn Johnson 100 be used together?
Resolution:
A special template is not needed, the closer drops down far enough on the door where it does not conflict with the GJ100 series concealed overhead stop. :
Where is the template for the 718 trims made after 2/28/2011 for Falcon/Monarch concealed vertical rod devices?
Resolution:
Templates for current 718 series trim can also be found on Falcon website:
Concealed vertical rod exit device
Resolution:
An exit device with rods concealed in the door and connected to top and bottom latches.:
Can the 283 strike be used with a metal frame with concealed vertical rod devices?
Resolution:
No, per the UL Compliance group, the concealed rod devices are only tested with the 338 strike with metal frames. This applies to panic and fire applications. The 283 strike may only be used ...:
CONCEALED VERTICAL ROD DEVICE
Resolution:
47, 5547, 8847, 9447, 9547, 9847, 9947, 3347A, 3547A, 9848, 9948, 9847, 9947, 9847WDC, 9947WDC, 8847-F, 5547, 5547WDC:
WOOD DOOR CONCEALED
Resolution:
WDC:
OVERHEAD CONCEALED
Resolution:
Concealed:
CONCEALED IN DOOR
Resolution:
Mortised: