full open position

RELATED FAQS

Question
Answer
When installing the arm; the gearbox shaft  and door must be at the (+90°) full open position. The following step are used to install the Sr. Swing (REG) push arm. Install the header and door brac...
The installation of the arms with the Benchmark and Falcon Swing Door Operator is similar to the Sr. Swing Series . The arms are installed with the main activation input shorted, the gearbox at the...
An inconsistent opening is normally caused by the arm not being installed correctly. The arm must be installed while the operator gearbox is in the full open position, and the door at 90° open posi...
When installing the arm; the gearbox shaft and door must be at the (+90°) full open position. The following step are used to install the Senior Swing (STD) pull arm. Install the header using app...
The regulation valves are designed to adjust the flow the hydraulic fluid in the closer which regulates the door closing speed through various phases of the closing cycle. The regulation valves h...
A 4600 (4630/4640) not opening to a full 90 degrees could be caused by a couple things: The Opening Force could be set too low. Try increasing the opening force adjustment on the controller a 1/...
The following items may cause the exit devices top latch from being held in the retracted position. 1. The top or bottom rods are out of adjustment. 2. The top latch hold back...
Following exit devices 2227/F, 33/3527A/F, 33/3547A/48A/F, 98/9927/F and 98/9947/48/F have similar rod adjustment procedures. All top latches control the bottom latch assemblies. When do...
LCN is pleased to announce the release of our new 36" Full Length Actuator. In situations where it is essential to be able to activate an automatic operator from different heights or angles (e.g....
Data Sheet includes an Overview, Dimensions, Construction, Application Chart, and Product Specifications.
The 8310-806K/R is used when a remote OFF/AUTO/HOLD OPEN is required and is normally used with a 4630/4640 CS (concealed switch) unit.
For wiring diagram see here.
The (SF) "Swing Free" arm allows the door to be put into hold open position, but then repositioned (swing free) to any other degree of opening without taking the closer out of the hold open mode. ...
An error - E04 - is an indication of a constant activation input from either the "Hold Open" switch or a "Wall Activation" switch when the 4600 power is turned on. This condition also occurs when l...
If manually it opens and closes fine, check to make sure one of the actuators is not getting stuck in the on position. Verify that the "Operating Indicator" LED's -- "POWER and SAFETY CLEAR" LED's ...
The hold open position on a "REG" or "EDA"  hold open arm is set with the door to a few degrees shy of the desired hold open point. To properly set, open the door 5° less then the desired hold open...
SE, electronic hold open
The ability to electronically supervise the state of specific conditions at a lock or opening, e.g., Lock/Unlock status, Deadbolt Position status, Battery status, etc.
How to:  What are the steps to adjust a door closer?Facts: All LCN and FALCON door closers will have 3 regulating valves and a spring adjustment.  All closers with a "Delay" feature ...
On May 1, 2013 the LM9000 lock was discontinued and replaced with the LM9300 Multipoint Lock. 
The Schlage LM9000 series lock was originally designed for use in FEMA (tornado) storm shelter openings and/or Florida Building code (hurricane) assemblies.  Doors, frames and hardware can be order...
  Specify either an L or B doors for use with the LM9000 or LMV9000 Specify the F frame for use with the LM9000 or LMV9000 Order the lock from Schlage as you would normally The concealed rods...
The hydraulic closer underneath the control box has 3 regulating valves (like any 4040 series hydraulic closer). Main Speed - adjust closing speed from 90° open down to 10°. Latch Speed - adju...
The Von Duprin 6000 series electric strike has a 12 or 24VDC solenoid with plunger, spring and impact washer as shown 6000 solenoid Make sure the solenoid spring and impact washer are not missin...
The UBC (Uniform Building Code) was a regional legacy building code which was superseded in most jurisdictions by the IBC (International Building Code). There may be some areas of the country which...
If the closer arm is touching the door, it is because the arm or the closer body is not templated correctly. Confirm dimensions are taken from the proper location and make corrections if needed. 
A Door Position Switch is a switch and magnet mounted on the door and frame that monitors the door status. If door is held open beyond rearm time or if door is forced open, alarm wil...
       "Opening Force" adjustment could be set to strong (high).  This adjustment is a turn pot adjustment which can be found on the controller.  Try adjusti...
A Chexit device could arm when the door is open but door may not close to secure the door unless a Door Position Switch (DPS) is connected to the device then the device goes into alarm after rearm ...
The "B" means "Bypass". The "80 or 140" is the degree of door opening from the fully closed position.  "B80" means the hold open feature is bypassed (will not hold open) until the door is opened...
No, LCN does not have an electronic hold open closer (SE/ME Series) that will provide a solid 180° hold open position. The 3130SE has an adjustable hold open position from 85° to 110° maximum. ...
The ME Series closer is a Multi-Point hold open device and will hold the door open in any position. The SE Series is a Single Point hold open device and will hold the door in one position. (deter...
If the Chexit device shipped prior to 8-24-2015  is not adjusted correctly ( Check vertical rod or Mortise finger) without using the door position switch and nuisance delay is&n...
 
Chexit devices shipped with motor after 8-24-2015. 1. When Chexit device is set for more than zero second rearm time (factory setting is 10 second rearm time) and device goes into alarm immediatel...
Chexit devices shipped with solenoid prior to 8-24-2015. 1.  When Chexit device  is set for more than zero second rearm time (factory setting is 10 second rearm time) and device goes...
Hold Open Closers & Magnets (Fire/Life safety products) provide a wide range of solutions.  Single or multi-point hold open closers Utilize an electromechanical closer. Hold the door o...
DPS, High Security