Question
Answer
How do you install the LCN 9540 Senior Swing (REG) push arm?
Resolution:
When installing the arm; the gearbox shaft and door must be at the (+90°) full open position. The following step are used to install the Sr. Swing (REG) push arm. Install t...:
How do you install the arms on a 9100 Series Benchmark operator?
Resolution:
The installation of the arms with the Benchmark and Falcon Swing Door Operator is similar to the Sr. Swing Series . The arms are installed with the main activation input shorted, the gearbox at the...:
Why would a Falcon 8200 operator have an inconsistent opening?
Resolution:
An inconsistent opening is normally caused by the arm not being installed correctly. The arm must be installed while the operator gearbox is in the full open position, and the door at 90° open posi...:
How do you install the LCN 9530 Senior Swing (STD) pull arm?
Resolution:
When installing the arm; the gearbox shaft and door must be at the (+90°) full open position. The following step are used to install the Senior Swing (STD) pull arm. Install...:
Is there adjustment limits on the regulation valves of LCN manual closers?
Resolution:
The regulation valves are designed to adjust the flow the hydraulic fluid in the closer which regulates the door closing speed through various phases of the closing cycle. The regulation valv...:
Why would a 4600 not open a full 90 degrees?
Resolution:
A 4600 (4630/4640) not opening to a full 90 degrees could be caused by a couple things: The Opening Force could be set too low. Try increasing the opening force adjustment on the controller a 1/...:
What would keep the vertical rod exit devices top latch from being held retracted in the open position?
Resolution:
Following exit devices 2227/F, 33/3527A/F, 33/3547A/48A/F, 98/9927/F and 98/9947/48/F have similar rod adjustment procedures. All top latches control the bottom latch assemblies. When do...:
Why would a 8310-806K be used in conjunction with a 4600 that has a on/off hold open switch?
Resolution:
For wiring diagram see here. :
What is the purpose of a Swing Free arm on a 4310ME?
Resolution:
The (SF) "Swing Free" arm allows the door to be put into hold open position, but then repositioned (swing free) to any other degree of opening without taking the closer out of the hold open mode....:
What is an error code E04 on an LCN 4600?
Resolution:
An error - E 04 - is an indication of a constant activation input from either the "Hold Open" switch or a "Wall Activation" switch when the 4600 power is turned on. This condition also occurs when ...:
What would cause a 4600 Series operator to open up and intermittently stick open?
Resolution:
If manually it opens and closes fine, check to make sure one of the actuators is not getting stuck in the on position. Verify that the "Operating Indicator" LED's -- "POWER and SAFETY CLEAR" LED's ...:
How do I set the hold open on my 4040 closer?
Resolution:
The hold open position on a "REG" or "EDA" hold open arm is set with the door to a few degrees shy of the desired hold open point. To properly set, open the door 5° less then the desired hold open...:
SINGLE POINT HOLD-OPEN
Resolution:
SE, electronic hold open:
Status Monitor
Resolution:
The ability to electronically supervise the state of specific conditions at a lock or opening, e.g., Lock/Unlock status, Deadbolt Position status, Battery status, etc.:
How do you adjust a door closer?
Resolution:
How to: What are the steps to adjust a door closer? Facts: All LCN and FALCON door closers will have 3 regulating valves and a spring adjustment. All cl...:
Can the LM9000 multi lock series be used in standard openings?
Resolution:
Specify either an L or B doors for use with the LM9000 or LMV9000 Specify the F frame for use with the LM9000 or LMV9000 Order the lock from Schlage as you would normally The concealed rods...:
How do you slow down the closing speed of the 4600 series operator?
Resolution:
The hydraulic closer underneath the control box has 3 regulating valves (like any 4040 series hydraulic closer). Main Speed - adjust closing speed from 90° open down to 10°. Latch Speed - adju...:
Why would an electric strike not stay locked when turned upside down?
Resolution:
The Von Duprin 6000 series electric strike has a 12 or 24VDC solenoid with plunger, spring and impact washer as shown 6000 solenoid Make sure the solenoid spring and impact washer are not missin...:
What is UBC 7-2?
Resolution:
The UBC (Uniform Building Code) was a regional legacy building code which was superseded in most jurisdictions by the IBC (International Building Code). There may be some areas of the country which...:
Why does the arm of my 4110 EDA touch the door when it is closed?
Resolution:
If the closer arm is touching the door, it is because the arm or the closer body is not templated correctly. Confirm dimensions are taken from the proper location and make corrections if needed. :
What is a Door Position Switch (DPS) for a Chexit device?
Resolution:
A Door Position Switch is a switch and magnet mounted on the door and frame that monitors the door status. If door is held open beyond rearm time or if door is forced open, alarm wil...:
What would cause my 4600 (4630/4640) Series operator to keep trying to open and squeal after opening to 90 degrees?
Resolution:
"Opening Force" adjustment could be set to strong (high). This adjustment is a turn pot adjustment which can be found on the controller. Try adjusti...:
Will CX re-arm if door is held open?
Resolution:
If a door position switch (DPS) is connected across the green and white wires of the old CX (green and red of new CX) the CX would go into alarm if the door is held open when it attempts to rearm.&...:
What does B80 or B140 indicate on an ME closer?
Resolution:
The "B" means "Bypass". The "80 or 140" is the degree of door opening from the fully closed position. "B80" means the hold open feature is bypassed (will not hold open) until the door is opened...:
Will a 4040SE open and hold at 180°?
Resolution:
No, LCN does not have an electronic hold open closer (SE/ME Series) that will provide a solid 180° hold open position. The 3130SE has an adjustable hold open position from 85° to 110° maximum. ...:
Why does my Chexit device open without sounding the alarm?
Resolution:
:
Von Duprin Chexit device keeps going into alarm by itself.
Resolution:
Chexit devices shipped with motor after 8-24-2015. 1. When Chexit device is set for more than zero second rearm time (factory setting is 10 second rearm time) and device goes into alarm immediatel...:
What are Hold Open Closers & Magnets?
Resolution:
Hold Open Closers & Magnets (Fire/Life safety products) provide a wide range of solutions. Single or multi-point hold open closers Utilize an electromechanical closer. Hold the door o...:
MULTI-POINT HOLD-OPEN
Resolution:
ME:
DOOR POSITION SWITCH
Resolution: