FALCON EXIT DEVICE MORTISE HOUSING

RELATED FAQS

Question
Answer
Yes. Both Schlage and Falcon SFIC mortise housings will accept 6 and 7 pin cores with no additional parts.
Effective July, 2014, there is no longer a specific modular cam part number for dogging. The Schlage modular straight cams come with two mouting holes that allow for the cams to be mounted inverted...
Issue:  Schlage SFIC mortise cylinders have potential for the driver pins to fall out affecting the ability to lock and unlock the device.Facts: Housings manufactured between 06/01/2...
This only applies to the full size interchangeable cores.  The SFIC mortise cylinders have part numbers for housings with construction cores (Disposable and Keyed).  Simply add (-ICX) to the end o...
1 1/8" mortise cylinders fit the 650 series keyswitch.  The 650 series keyswitch when ordered with the cylinder, will come complete with the correct cylinder, cam, and any required blocki...
If blocking rings (PN 36-079) are needed, specify dimensions when ordering. See below for blocking ring (PN 36-079) dimensions.  Blocking Ring  Specify Dimension  1//8" ...
20-059 is the standard straight cam FSIC housing only used with Von Duprin, Monarch, and other straight cam applications. 30-032 is the straight cam FSIC housing only for the outside of the Schl...
ISSUE: After some use the plug will begin to project from the cylinder face and will ultimately pull completely out. ROOT CAUSE: In a dogged application the cam was rotated 180 degrees which ...
There are different mortise cylinder length options depending on the cylinder type. Below is a list of available options for conventional, FSIC, and SFIC cylinders, as well as the convent...