ELECTRIC LOCK FAILURE

RELATED FAQS

Question
Answer
The Senior Swing control box has a built in (programmable) relay output for connection to a Fail Safe/Fail Secure electric strike/maglock or to an EL Device power supply.
Applies to L9090EL/EU, L9091EL/EU, L9092EL/EU, L9093EL/EU, L9094EL/EU, L9095EL/EUOvervoltage will cause the lock to shut down for approximately 5 minutes to allow the circu...
Information on low battery threshold and nuisance delay is noted below: New firmware now has improved levels. - These are approximate values/levels which change with measurement meters and measure...
AD400/AD200/AD250 After ADFwPkg 2.17.0 - June 2011 4 Battery Holder New batteries = 6.2 VDC Low battery threshold is 4.7 VDC for SM & MT - and 3.7 VDC for MAG and PROX (USB stops working at 4...
    AD400/AD200/AD250 After ADFwPkg 2.17.0 - June 2011 8 Battery Holder New batteries = 12.4 VDC Low battery threshold is 7.2 VDC Critical battery threshold is 6.9 VDC Coin cell = new/...
CO2004 Battery Holder (ONLY) New batteries = 6.2 VDC Low battery threshold is 4.2 VDC Critical battery threshold is 3.9 VDC Coin cell = new/full is 3.0 VDC, low is 2.8 VDC
CO2504 Battery Holder (ONLY) New batteries = 6.2 VDC Low battery threshold is 4.2 VDC Critical battery threshold is 3.9 VDC Coin cell = new/full is 3.0 VDC, low is 2.8 VDC
  CO200 & CO250 Disable coin cell Nuisance delay and blink, With CO.A.7 and SUS 4.10.2 or newer for CO200 and CO250, you can use the SUS/HHD, under Lock Properties, Edit, to de-select, DISABLE, t...
Thermal Bow is a temporary condition which occurs in metal doors mainly due to the temperature differential from one side of the door to the other. This may occur in exterior doors when direct sun ...
All Keypad ONLY credentials with firmware versions between 2.9.2 and 2.11.0 should be updated to the latest firmware available at www.schlage,com/support.
A firmware issue with Keypad ONLY credential firmware, versions 2.9.2 through 2.11.0 and manufactured between 9-9-2010 and 1-5-2011 will exhibit poor battery life.
The Keypad ONLY credential Reader (KP) can prevent the reader from entering its low power sleep mode - with firmware versions 2.9.2 through 2.11.0
A Technical Note has been generated to document one method of measuring battery current. See the attachment HERE.
The 5100 electric strikes are for use with cylindrical locks only.  Instead use the following:6211 electric strike is used with mortise lock without deadbolt on a new single door, hollow ...
ND locks shipping on or after January 30, 2017 no longer require the use of the soft durometer spacer. Lever installation on the redesigned ND locks should not be difficult.
For ND locks shipping prior to January 30, 2017, the addition of the soft durometer spacer (SDS) on August 15, 2012 did affect the installation of the lever.  Ultimately, removing th...
Cylinder pin information is very unique to the device and application and requires a unique solution. If you have questions related to cylinder pin, please e-mail your request (including a descript...
The Schlage full size interchangeable core (FSIC) prepped B560F, B561F, and B563F deadbolts all require a UL fire cup (R) in order to be UL listed.  This fire cup is s...
The Locknetics 9100 series electric strikes are replaced with Von Duprin 6211 and 6210 electric strikes.   The 6211 is used if the frame is being replaced. The 6210 is for ...
The center line of the L9000 mortise lock is 7/8" above the center line of the 6211 electric strike. This is the "C" dimension given on the second page of the 6211 template.
Von Duprin 6223 electric strike is the most common closed back strike or the 6221 for open back strike on inactive leaf that can be used with Schlage L9000 or Von Duprin 7500 mortise lock.
The Von Duprin 6210 electric strike was designed for retrofit applications and will not work with the Falcon MA series lock when strike and lock body are mounted at standard locations (centerline o...
The 6211 would be the most common electric strike to be used with cylindrical locks on a single door application.  Check the template to confirm compatibility with specific cylindrical lock model n...
EL: Electrically Locked (Fail Safe), locks when power is supplied and is unlocked when there is no power. EU: Electrically Unlocked (Fail Secure), unlocks when power is supplied and is locked when...
The Von Duprin 6300 surface mounted electric strike is only available as Fail-Secure.
The keycam may have failed, example here, the latest design keycam can be easily identified as the colored changed to black. Replace either the keycam or chassis as needed to r...
 This could also happen if the tailpiece isn't installed in a KIL, FSIC, or SFIC cylinder.  The FSIC driver also could have come loose from the core in the spindle.
CO-100 now allows the PIN code length to be changed manually.  Each CO100 has a label that indicates its firmware revision.  Firmware revision 2.5.0 or higher support these...
CO-100 PIN length can range from 3 digits to 6 digits with firmware version 2.5.0 and higher.
Procedure to change PIN length: 1. Press {programming code (default is 97531)} then {*}.2. Press {99} then {*}, to enter Special Function Length Menu.3. Press {4} then {*}, to enter Pin Length M...
CO-100 now has NEW lock status reporting capabilities. Battery status, firmware version, hardware version and PCB serial number. See instructions below for these status menus.
If the  AD300  power is not correctly connected it may not communicate or other wise function correctly.The AD-Series locks must be hard wire powered through the comm board. It is not com...
The 6216 electric strike was designed only for use with only the Folger Adams 310-3-1 mortise lock with deadbolt. The dead bolt must be retracted manually for the the strike to operate.
Storeroom Lock with Vandlgard - Electrically Unlocked (Fail Secure) - Lever is continuously locked until unlocked by key or electric current. Auxiliary latch deadlocks latchbolt when door is closed...
Troreroom Lock (Electrified - Fail Secure) - Outside Lever is continuously locked mechanically until unlocked by electric current. When locked, key retracts latch. Inside lever is always unlocked a...
A thumbpiece, knob or lever trim left in the unlock position would be locked when the Chexit is armed and unlock when the Chexit device is disarmed. To keep the outside trim in the lock p...
The new motor driven ND electrified locks shipped after March 14, 2016 do not require a solenoid. The Schlage ND-Series electrified locks shipped prior to March 14, 2016 would have used a...
Storeroom Lock (Electrified - Fail Safe) - Outside Lever is continuously locked electrically. Unlocked by switch or power failure. When locked, key retracts latch. Inside lever is always unlocked ...
The following common wiring diagrams are available:One Single Door with Panic BarElectric Latch Retraction, with Auto OperatorDelayed egress - Fire Rated ApplicationAuto Operator and actuatorElectr...
Electronic Protocols:Access Control Door with electric trimAccess Control with electric strike Access control with electric strike and LCN 4600 automatic operatorAccess Control with remote Loc...
Storeroom Lock with Vandlgard - Electrically Locked (Fail Safe) - Lever is continuously locked electrically. Unlocked by key or power failure or switch. Auxiliary latch deadlocks latchbolt when doo...
First, perform a Factory Default Reset  Next, close the app, turn off Bluetooth (swipe up from the bottom of the screen, tap the Bluetooth icon). Turn Bluetooth back on.  Reop...
Update your lockset using ADFwPkg 2.19.0 or higher.  This new firmware update resolves this programming error problem (E701) and the error will no longer be presented.
Procedure for the L9090EL/EU, L9091EL/EU, L9092EL/EU, L9093EL/EU, L9094EL/EU, L9095EL/EUThese devices have a selectable switch in the upper right corner of chassis.  Simply move the switch to ...
Procedure for the L9080EL/EU and L9082EL/EUTo modify an electrified L9000 from EU to EL or EL to EU move the link pin to the appropriate location indicated below in Figure 1.  
Follow the steps below to troubleshoot the problem. Measure the voltage at the electric strike. If the strike is FSE and not locking there should be no voltage at the strike and if it is FS there ...
Electrical hinges or a power transfer units are the most commonly used practices to run electric power to locks and/or strikes. Electric Hinges: Most electric hinges will fit into a standard 4 ...