do we offer deadbolt monitoring on electric strikes

RELATED FAQS

Question
Answer
The DS is Dual Monitor Switch for Von Duprin 6000 series electric strikes. DS option cannot be added to a Von Duprin 6000 series electric strikes in the field. It is only available factory inst...
The Von Duprin 6300 surface mounted electric strike is compatible with 55 rim device.
The Von Duprin 6000 series electric strike can be converted by ordering the appropriate kits below.  Kits include the solenoid, plunger, spring, and washer. 6000 Series solenoid Kit 12VDC -...
No, due to the gate and backbox not being able to be sealed to keep water out of the electric strike a weather proof version is not available.
The 6216 electric strike was designed only for use with only the Folger Adams 310-3-1 mortise lock with deadbolt. The dead bolt must be retracted manually for the the strike to operate.
Schlage does offer rabbetted latch and strike kit: Part number, 39-030, for cylindrical locks and deadbolts.  Part number, 10-075, for the L9000 mortise locks. Monarch does not offer rabbette...
Von Duprin doesn't offer any electric strike to fit into 1 1/2" aluminum/metal faced frame.  Minimum requirement to install 6211/6211AL is 1 15/32" mortise depth.
The 5100 electric strikes are for use with cylindrical locks only.  Instead use the following:6211 electric strike is used with mortise lock without deadbolt on a new single door, hollow ...
The Von Duprin 2670 Guard X does not have a spring loaded latch bolt, it is a dead bolt and will not operate with any electric strikes.
The power supply output in the 7900 series control box is a 12VDC output, rated at (1/4A) 0.250A. It cannot be used to power a strike or maglock. You need to have a separate power supply for the st...
An electric strike or maglock (24 volt only) can be wired to a Senior Swing 2800/9500 series operator using the P10 Lock Interface cable. To power the 24VDC electric strike or maglock off a LCN Se...
The 4600 Series operator has both a 12VDC and 24VDC output rated at 1A (combined load) to power strikes, maglocks, and other devices, but an EL device "always" has to have a separate PS914-2RS Seri...
The Von Duprin 6210 electric strike was designed for retrofit applications and will not work with the Falcon MA series lock when strike and lock body are mounted at standard locations (centerline o...
The center line of the L9000 mortise lock is 7/8" above the center line of the 6211 electric strike. This is the "C" dimension given on the second page of the 6211 template.
Electrical hinges or a power transfer units are the most commonly used practices to run electric power to locks and/or strikes. Electric Hinges: Most electric hinges will fit into a standard 4 ...