co series motor
”
RELATED FAQS
Question
Answer
Can you use a Senior Swing controller as a replacement for an obsolete Mid Swing controller?
Resolution:
The Mid Swing was discontinued Sept. of 2009. The Sr. Swing control box has the power boost feature which the Mid Swing control box did not have. If you replace only the Mid Swing control box...:
Can the credential reader be changed on a CO-Series lockset?
Resolution:
A Credential Reader MAY be replaced with another Credential Reader of the same type; however, a Factory Default Reset must be performed before the lock will function properly.:
What would cause a Senior Swing to open only 10 degrees and then close?
Resolution:
Issue/Symptom – upon receiving an activation input the Sr Swing gearbox opens only about 10 degrees and then returns to the close position. Unit will never learn opening nor function pro...:
I get three green blinks of the Schlage key and it says motor stall on my SUS/HHD during diagnostics?
Resolution:
Just align the triangles per the installation instructions to allow full motor movement. - This will eliminate the SUS motor STALL report. - This will eliminate the three ...:
Why can't I LINK my AD-Series lock?
Resolution:
1. To put the AD400 in LINK mode, hold down the RTE (Lever or crash bar see below) and press the # key on the key board, or present a card to the reader. ...:
Resetting a CO200 / CO250 Series Lock back to Factory Default Settings
Resolution:
1. Press and hold the Schlage button. Wait for the lock to beep twice and two green blinks of the Schlage button, indicating a confirmation. 2. After confirmation signals, release the Schlage butt...:
Why doesn't full rotation of the AD or CO Series Exit Trim (993) outside lever fully retract the Von Duprin 98/99 Exit Device latch?
Resolution:
- AD Series and CO series products require that the Night Latch (NL) screw is installed in the exit device. Be sure this screw is installed- Exit hardware and strike must be properly mounted ...:
Why can't I order an AD-Series or CO-Series mortise deadbolt with a classroom/storeroom (70) function
Resolution:
* NOTE: the AD300/400 devices simply communicate the change in Deadbolt Position status to the Host software. The software then decides what action should or should not be taken at the device. :