can an exit device be hurricane rated
”
RELATED FAQS
Question
Answer
Can Steelcraft doors be prepped for the 98/9949 Concealed Vertical Cable Exit Device?
Resolution:
Yes, as an option, Steelcraft doors are available with factory prepared for the 98/9949 Concealed Vertical Cable Exit Device.L, B, CE, T and CE-Series doors are available factory preparedDoor prepa...:
What is (SD) Special Dogging?
Resolution:
SD is Special cylinder dogging in the center case of 98/99 rim and vertical rod non fire rated devices and is available with standard, EL, QEL, CX and ALK.:
Is there a fire rated version of the 33A/35A rim device?
Resolution:
There is not a fire rated version of the Von Duprin 33A/35A rim device. Only the vertical rod devices (33/3527A-F, 33/3547A-F, 33/3548A-F) can be fire rated.:
Where do I install my Auxiliary Fire Latch (AFL) in a Less Bottom Rod, Fire Rated (LBR-F) exit device?
Resolution:
Installation should be 6" from bottom of the door. See attached templates as reference. T-5494 for HM Doors W-5494 for Wood Doors:
Is the Von Duprin 1609 strike fire rated for pairs of doors?
Resolution:
The Von Duprin 1609 cannot be used on a pair of fire rated doors. We recommend using the Von Duprin fire rated mortise exit device in lieu of the rim device such as the Von Duprin 5575-F,...:
What is AFL on fire rated LBR exit devices?
Resolution:
AFL stands for "Auxiliary Fire Latch" on fire rated exit devices.:
Can dogging be added to a Von Duprin fire rated exit device?
Resolution:
No, dogging cannot be added to a fire-rated mechanical exit device. Fire rated devices can be only electronically dogged and drop during fire activation.:
Are any of the DOM exit devices rated?
Resolution:
Fire rated devices are not an option.:
Is the Von Duprin Guard-X exit device fire rated?
Resolution:
The Von Duprin Guard-X exit device is not fire rated because the deadbolt is not spring loaded. Therefore, there would be no positive latching as required on a fire rated opening. :
FIRE RATED MORTISE LOCK FIRE EXIT DEVICE
Resolution:
9875-F Series,9975-F Series , 5575-F, 8875-F:
What is the Multi Point LM9300 Series?
Resolution:
MultiPoint locks are three-point locking systems that secure the door at three points – top, bottom, and traditional center latch location. Operating just like traditional locks, MultiPoint locks...:
When are Panic Devices required?
Resolution:
The use of Panic Hardware and/or Fire Exit Hardware is required by the International Building Code (IBC) and NFPA 101 – The Life Safety Code, depending on which code and which edition of the code i...:
Can the CD cylinder dogging and RX switch be ordered with 33/35 or 98/99 exit device?
Resolution:
This can be done ONLY with non fire rated exit devices.:
Can the 9947-F be converted to 9947WDC-F
Resolution:
Fire rated exit devices can't be modified to different model per UL requirements.:
Can a Von Duprin 7500 lock and device replace a Schlage L9000 series lockset?
Resolution:
While they are both mortise locks they are not interchangeable. You would NOT be able to use a L9000 with a VD panic device. You would NOT be able to use a VD 7500 with Schlage lev...:
Is there a Fire-Rated 33A Rim device?
Resolution:
The Von Duprin 33A/35A rim narrow style exit device is only for non rated openings and fire rating is not available with this device. The Falcon F24-R is a narrow style fire rated exit device T...:
How do I add mechanical dogging to my Von Duprin EL device?
Resolution:
HD-EL (Hex Dogging Electric Latch Retraction) solenoid and plunger can be replaced with standard EL solenoid and plunger on non fire rated exit devices, but this should not be used on a daily basi...:
What is the difference between LR and PL latches on Von Duprin 8827 exit devices?
Resolution:
ES (electric strike) latch is only used with the 8827 less bottom rod on a non fire rated exit device with a 6111 electric strike.:
Can I put an old style hex dogging kit (050153) on my 99 panic device?
Resolution:
We don't recommend to use the old style hex dogging kit into the new 98/99 exit device but it would fit as long as the device is not fire rated.:
Do we offer HD-QEL?
Resolution:
We offer a couple different HD-QEL options:Hex key dogging (HD) is now available with Von Duprin non fire rated QEL33A/35A/98/99 electric exit devices that were shipped after De...:
Can I use CD and ALK on a 98/99 series Von Duprin?
Resolution:
Standard 98/99 exit alarm ALK devices are available with cylinder dogging option as of October, 2011. The device can be ordered standard with cylinder dogging and exit alarm ALK opti...:
What BHMA Grade is the Falcon 25 Series exit device?
Resolution:
A copy of the BHMA Directory Listing can be viewed in the online Certified Directory on the BHMA web site. BHMA:
Do 25 series exit devices have a hurricane rating available?
Resolution:
Order the 25 device with the "HH" prefix as described in the device options in the Price Book.:
What exit device is weather rated?
Resolution:
Exit devices are not designed for exterior application. If used in an exterior applications then a powder coated finish on the 33/35 and 98/99 series are recommended for exterior applications. ...:
Is the XP98/99 device hurricane rated?
Resolution:
The Von Duprin XP98/99 exit device is hurricane rated (non-impact rated and impact-rated) for single doors or pairs of doors. Hurricane ratings vary by location and application. ...:
Which mullions are Hurricane Rated?
Resolution:
The HH9954 is the only Von Duprin hurricane impact-rated mullion. Hurricane ratings vary by location and application. Be sure to check with the local authority and/or the Regional Allegio...:
Where can I find hurricane ratings for Schlage and Falcon?
Resolution:
There are several Schlage and/or Falcon locks that have been tested and approved for this application. For Commercial use the locks have been tested and approved as ...:
Can a panic device be converted to a fire-rated device in the field?
Resolution:
A standard exit device can't be modified to a fire rated exit device. In order to get a product with the UL fire label, a new device must be purchased. This is a UL requirement.:
Are glass lights available in the H-Series door?
Resolution:
Steelcraft offers all the standard lights as well as special size glass lights in the H-series door. Effective April 1, 2012, (Bulletin # B-100.12) the default for Dezigner Trim in H-Series D...:
Will the 6300 electric strike work with 88-F or the 88 rim panic?
Resolution:
Von Duprin 6300 electric strike will operate with 88 rim but not 88F fire rated exit devices.: