Question
Answer
What is the LCN fluid - "Liquid X" - temperature range?
Resolution:
The LCN closer fluid "Liquid X" will perform without variation between: -30° F to +120° F - for manual closers. +35° F to +120° F - for electrical closers and a...:
How do you change a 9130 Benchmark to a 9140 Benchmark?
Resolution:
The only difference between the 9130 and 9140 Benchmark operators are the arms. To convert a Benchmark 9310 (pull) to a 9140 (push), order a 9140-3077 push arm assembly ...:
What are Pneumatic Automatic Operators?
Resolution:
Pneumatic Automatic Operators are used in areas where electrically operated devices are not convenient or permitted. Consists of a modified, heavy-duty door closer for manual oper...:
Does LCN repair or sell rebuilt closers?
Resolution:
Because of the new extended LCN warranties and the desire to be consistent across the entire Allegion premium brands, LCN will be moving away from offering an out-of-warranty repair service beginni...:
Can a Senior Swing 2850 or 2860 be used on a Double Egress (DE) door?
Resolution:
The overhead concealed operators (2850/2860) will not work on a Double Egress frame because the doors are not in the same plane. You will have to use the surface mount (9553 / 9563) on Double Egres...:
What maintenance is required for an LCN closer?
Resolution:
Closers mounted according to LCN installation instructions require no periodic maintenance or seasonal adjustments. Monthly, quarterly, and annual visual inspections are recommended for Fire/...:
Can a Cam Lift hinge be used with LCN closers?
Resolution:
Cam Lift hinges can only be used with LCN door closers that have a "Regular" or "Reg hold Open" style arm. Manual Closers:Maximum lift dimension is 3/4".Can not be use (H)EDA, CUSH, or T...:
What are Electro-hydraulic Automatic Operators?
Resolution:
Electro-hydraulic Automatic Operators are: Designed for manual opening applications where there is occasional need for automating the door to meet ADA requirements. Electrically powere...:
When did we start shipping the Senior Swing, Benchmark, and Falcon operators with the ES Filter?
Resolution:
On the Benchmark, if there is line noise from a strike then the unit will lose it's hold open time. Adding the ES Filter, which is a diode, will resolve this issue and the unit will hold it's...:
How do I get a Size 1 (ADA) closer to close against air pressure?
Resolution:
If an Size 1 (ADA) closer is set to 5 lbs. opening force, it will only have about 3 lbs. (60/70%) closing force. If the closer will not close against air pressure, but the ADA requirements have to ...:
What are ElectroMechanical Automatic Operators?
Resolution:
ElectroMechanical Automatic Operators are designed to automatically open when activated. The Benchmark Series are Medium Duty "Commercial" automatic operators, often used on of...:
Why would a 4600 not open a full 90 degrees?
Resolution:
A 4600 (4630/4640) not opening to a full 90 degrees could be caused by a couple things: The Opening Force could be set too low. Try increasing the opening force adjustment on the controller a 1/...:
Can an auto operator be installed on a Dutch door?
Resolution:
Yes, an automatic operator can be installed on a Dutch door. The operator must be installed on the top leaf of the Dutch door. Only the top half will open unless the top and bottom leaves (se...:
What could cause a 9100 Series Benchmark operator not to open when the actuator is pushed?
Resolution:
If the 9100 Series Benchmark operator does not open when the actuator is pushed: Verify the unit has 120 volts applied to it. Verify the the power light on the control box is on. If not, check ...:
What would cause my 4600 (4630/4640) Series operator to keep trying to open and squeal after opening to 90 degrees?
Resolution:
"Opening Force" adjustment could be set to strong (high). This adjustment is a turn pot adjustment which can be found on the controller. Try adjusti...:
What operator is best for high traffic automatic use.
Resolution:
The Senior Swing 9500 or 2800 series operator is designed to for "High Traffic - High Abuse" areas.:
How do I get service on my Astro Swing operator that isn't working properly?
Resolution:
LCN does not does not have or supply any information for the old (obsolete) "High Energy" Dor-O-Matic Sliding doors, Bi-Fold doors or Astro Swing doors. You MUST be AAADM certified to work on, or g...:
What is a Senior Swing 9540 RF?
Resolution:
The Senior Swing Series used to have a 2 gearbox options, a "standard force" (15 lbs) and a "RF - reduced force" (11 lbs). In November 2009 RF option was eliminated and we made the standard gearbox...:
Can the 4630/4640 cylinder only be replaced?
Resolution:
The 4040(XP) door closer can be used as a temporary replacement in a 4630/4640 operator to provide manual control of the door while the 4630/4640 closer cylinder is being repaired or a replacement ...:
What would cause a Falcon 8200 (8230/8240) operator to slam the door closed?
Resolution:
The Benchmark 9100 series and Falcon 8200 Series operator will allow the door to slam if: The motor is not connected (plugged into) the controller as the closing speed is controlled by a c...:
What power operator is recommended/used for occasional activation with mainly manual traffic?
Resolution:
The 4630/4640 Series operator is designed/recommended for a door that will see mostly manual traffic with the occasion automatic/ handicap operation.:
What would cause a 4600 operator to click a few times when the actuator is pushed, but not open the door?
Resolution:
If a 4600 clicks, but won't open the door: Verify proper connection of all the control box connectors. Verify correct manual operation of door. Verify actuator connections and any strike/maglo...:
How do I program my device?
Resolution:
The programming processes for Allegion devices can be both product and features specific. Some products programming processes are electronic in nature, others are physical in nature. &nb...:
What is the difference between a 4630 and 4640?
Resolution:
4630 Single Arm/Track style. Mounted on the Pull Side of the door. Non Handed 4640 Double Arm style. Mounted on the Push Side of the door. Non Handed:
What power supply do I need for my 2 QELA devices with LCN auto operator?
Resolution:
Use the PS902-2RS power supply with LCN auto operator on single door, PS904-2RS power supply on double door and PS904/906-2RS-2RS for 2 pair of QELA is required for basic operation with a...:
Can a 9500 series operator on the push side be used with Cam lift hinges?
Resolution:
The Senior Swing will work with Cam Lift Hinges as a PUSH SIDE MOUNT 9542/9553/9563 only. Maximum 3/4" lift. Maximum 15 pounds force to push door up the Cam Lift Hinge. Cam Lift Hinges WILL NO...:
Which arm is the same as the 4640 regular arm?
Resolution:
The 4640 Regular arm (4640-3077) is the same as: 4040 Long Arm 4820 Regular arm. The arms listed above are for reveals up to 4 1/2" and have a 8 3/8" long rod and shoe. 4640 Long arm ...:
Where does the 8310-877 safety sensor attach to the Senior Swing controller?
Resolution:
The 8310-877 Bodyguard Safety Sensor attaches (plugs in) to the P1 connector on the Senior Swing controller. The 8310-846 (761462-00) wiring harness "included" with the 8310-877 safety sensor is us...:
What is the opening force of a 4600 Series (4630/4640) operator when used manually?
Resolution:
The manual opening force on a 4630/4640 will be approximately 8.5 lbs to 14 lbs depending on the spring setting.:
What would cause a Senior Swing to open too far?
Resolution:
The Senior Swing operator is designed to power open the door to 90°. The built in dead stop (in the gearbox) prevents it from opening any further. If the Senior Swing operator is opening to far (pa...: