The minimum stile for each lock will depend on the backset and the rose diameter/escutcheon width.  See the Schlage Minimum Stile Guidelines  for the minimum stile for each...
To determine Actual Door Size, the following values are subtracted from nominal door size (frame opening/order size) Actual Door Size: The largest measured width by height of the door leaf as m...
Butt hinges can be used on  doors up to 4' wide and 200 pounds.  There is no maximum door height, just need to add a hinge for every 30" or part there of over 7'.
The maximum door width that pivots have been tested is a 4' wide door.  Any door greater than 4' would shorten the life of the pivots. There is no maximum door height, for offset pivots the ru...
Monorail cutouts are typically the upper corner of door. Channels are cut to size welded into door held flush to cutout. We do not supply any covers or plates to finish.
The size monorail cutout is 8" wide x 24" high
Monorail cutouts are only available for non fire rated applications.
"PUSH SIDE" application: Minimum 52" wide pair, with neither door being less than 21" wide. "PULL SIDE" application: Minimum 60" wide pair, with neither door being less than 30" wide.
The Minimum single door opening should be 26.32" and use the 299 or 499F strike.