Can you mount an LCN 4010 with GJ100 series stop?
Resolution:
ST-1544 is needed to mount the 4010 door closer and GJ 100 or GJ 410 series concealed overhead stop together.:
How many 4040 SE's can be powered from a 4040SE-3210 transformer?
Resolution:
LCN recommends that only 2 to 3 -- 4040SE or 4310/4410ME 24V closers be powered from one 4040SE-3210 transformer. :
What is an old Dor-O-Matic 99000 series operator?
Resolution:
The 95000 Series Ascent operator(also known as the Benchmark I) is an obsolete operator that was made by Dor-O-Matic who is now out of business. Only the arms from a Benchmark III operator will wor...:
Can the Schlage L or LP section key blank be cut in the field?
Resolution:
Schlage does not recommend cutting the L or LP section key blanks in the field. Below are some details.Non Primus:In the classic family of keyways the "L" key section is the highest level key...:
Are adjustable base anchors provided with frames that are prepped for existing opening anchors?
Resolution:
No, an adjustable base anchor is not supplied on frames with existing opening anchors. The anchor design for use in existing masonry walls, is a pierce and dimple in the frame soffit for 3/8"...:
What options are available on the CE-Series doors?
Resolution:
CE Series door in a variety of embossed panel designs and gages. The CE series embossed panel doors also offer a wide range of specifiable options including sizes, and hardware prepar...:
Can the handing be changed on a Von Duprin 373L trim ?
Resolution:
Changing the handing on a Von Duprin 373L trim requires following parts: LHR to RHR requires 090092 ( Package of 4 springs ) and 050597 ( back plate assembly ). RHR to LHR requires 090091 ( Pa...:
Does LCN still sell the 761469 retrofit cable, part # 8310-887?
Resolution:
LCN Sr Swing retrofit cable and kit (8310-887 and 8310-3134) were both obsoleted early 2018. The retrofit cable -887 was for activation and was included in the retrofit kit -3134. They ...:
What is the maximum degree of opening you can template a 4110 Cush closer?
Resolution:
The 4110 Cush closer can be templated for 85°, 90°, 100°, and 110° maximum as standard templates.The 4110 if ordered by ST-3220 will allow templating to 135°:
What is the difference between a 4630 and 4640?
Resolution:
4630 Single Arm/Track style. Mounted on the Pull Side of the door. Non Handed 4640 Double Arm style. Mounted on the Push Side of the door. Non Handed:
«