Question
Answer
What is the tallest door that can be ordered for vertical rod devices?
Resolution:
Tallest door that can be ordered for vertical rod 22/33/35A/94/95/98/99 exit devices is 10' on single or double metal doors non fire and fire on double doors only...:
What is the difference between the 376T and the 360T trim when it is used with Von Duprin 33/3547A exit device?
Resolution:
The 376T trim activates and connects to the 33/3547A top rod. The 360T activate and mounts to the 33/3547A center case.:
Does the 4010T, 4020T, and the 4110T use the same cylinder body?
Resolution:
The comparisons of these products are shown below. The 4010T, 4020T, and 4110T cylinders have a longer pinion shaft than the 4010, 4020, and 4110 cylinders. The 4010T,4020T, and 4110T all use t...:
What is the minimum top rail needed for the 4111 EDA/HEDA?
Resolution:
The minimum top rail required to mount a 4110 closer is 5-1/8" measured from the stop of the frame. If the top rail is less than 5-1/8" the 4110-18 drop plate is required.:
Are the 4011 and 4021 closers the same?
Resolution:
The 4011 and 4021 use the same closer body but other components are different. The 4011 mounts "pull" side. When ordered as a 4011, it comes with a 6-3/8" rod and shoe, pull side instruction...:
What arm can I use for the old LCN 4030/4130 closer?
Resolution:
The old 4030/4130 closers and arms are obsolete, there is nothing to replace them. No arm from other closers will fit There is no closer that can replace the old 4030 series closer with the exa...:
What is the LCN fluid - "Liquid X" - temperature range?
Resolution:
The LCN closer fluid "Liquid X" will perform without variation between: -30° F to +120° F - for manual closers. +35° F to +120° F - for electrical closers and a...:
How many cycles or card presentations are the AD-Series and/or CO-Series Magnetic Card Credential Readers tested to?
Resolution:
Both the "Insert and Swipe" type magnetic credential readers have been tested to BHMA A156.25 requirement of 500,000 cycles/card swipes):
IS the MBS built into the M series of maglocks IS the magnetic bond sensor built in tho the M490.
Resolution:
These items are included in the P model of the M series:
Are parts available for PB405 / 405S powerbolts
Resolution:
No - parts are not sold separately:
«