Question
Answer
What does the Reset button on a Chexit circuit board do?
Resolution:
The circuit board in a motor driven Chexit delayed egress exit device and DE5300 delayed egress controller manufactured after 8/24/2015 has a button labeled RESET. This is located between t...:
What are the part numbers for the screw packs for the ND series locks?
Resolution:
The part numbers are: N123-020 Mounting, all functions except ND170, Contains the following: (4) C603-897 (2) C603-256 (2) N523-021 (1) M504-271 N123-040 Mounting, ND170: Contains ...:
What tool is needed for the NDE security screw?
Resolution:
You will need the T-15 and the T-20 Secure torx tool. You can order them from us. Part #: L283-121 Contains: (2) Armor screws, #8-32 x 1/4” (T-15) (2) Strik...:
Will the NDE locks read HID iClass SEOS credentials?
Resolution:
No, SEOS CSN is different every read, we can't read them even if iClass CSN is enabled. :
How does the RU/RM check and update its internal time?
Resolution:
It should get a command from ACP and GWE will push the update to the device.:
AD300 wired to PIB300, if you short out strike input and ground, should the AD300 unlock?
Resolution:
Yes, the AD300 should unlock if the wiring between the PIB300 and AD300 is correct and they are communicating.:
Is the GF3000 UL listed?
Resolution:
The GF3000 is UL listed for UL10C which is fire rating. At this time, it is not rated for UL294.:
On the M490DEP are the wires going to the Alarm, opened or closed?
Resolution:
Alarm is an OUTPUT. The contact closes when the lock goes into full alarm. When lock is not in alarm, the contacts are open :
How do you wire up an M490DE to a 900-4RL with a FA on it so it will drop power in a fire alarm condition?
Resolution:
Any powered outputs on the 900-4RL will lose power if the FA board on the 900-4RL opens, use a dry relay to trigger release input, the Maglock should be on NO1 and C1 and a jumper on I1 and SC. ...:
What are the measurements of the narrow stile and regular style face plates for the 653?
Resolution:
The single gang is: 2 3/4" x 4 1/2" The narrow style is: 1 3/4" x 4 1/2" :
«