Does a key for a lock meet ADA standards?
Resolution:
Although the ADA standards address operable parts of locks – like thumbturns, keypads, turn-buttons, and of course, knobs and levers, keys are not covered by ADA. ADA requires door and gate h...:
Can a door position switch be ordered with an L series lock?
Resolution:
As of January 02, 2017, Schlage non-deadbolt mortise locksets can be ordered with a door position switch. To order the door position switch with an L series lockset specify DPS in the o...:
How is the cosmetic back plate cover different from the mini mullion back plate?
Resolution:
The intent is to cover the footprint left by a previous reader, more so if the previous reader was a larger one. :
Does the M490G maglock come with the L bracket?
Resolution:
Yes, The M490G has the TJ bracket in the box.:
On an AD400-MS converting from a BD to PD, does the escutcheon need to be replaced?
Resolution:
Yes. 46928750, which is the new outside escutcheon they will need. The BD uses the smaller hole CY escutcheon so they will need to change to the larger hole MS escutcheon. Make sure the finish is ...:
What latch can be installed with a NDE80 lock on a fire rated door as to not lose the fire rating?
Resolution:
The NDE80 with 13-047 latch is fire rated. The only reason to use 14-042 latch is in a double door situation with no mullion where one door latches to the other.:
What mechanical lock will fit the prep of an AD-250-MD?
Resolution:
An L 9000 series would be the lock, but all of the prep for the lock would require many wholes to be filled or fixed. The body of an AD lock requires multiple holes to be drilled in addition to th...:
When I present my card to the Ad400-993R it goes into a linking state
Resolution:
· Confirm the RX switch is wired as open state, if wired in closed state and you present card it reacts as if you are trying to link lock to the PIM:
What is the part number for the coring fixture for the AD/CO locks
Resolution:
· IRDORCOR 3/8” coring fixture · Can be found on page 88 Schlage Electronics Price Book ...:
Are AD Series Locks "Weather Proof"?
Resolution:
No. Weather resistant and suggest to be installed in a protected area if outside.The outside of the AD is rating for outdoor weather temps but it cannot be mounted fully outdoors.:
«