What is the part number for a hex dogging shaft for Falcon Dor-o-Matic 1690 or 1790 exit device?
Resolution:
The part number for 1690/1790 hex dogging shaft is shaft.101:
Does the 672 / 692 REX require the 788-12 / 788-18 door loop?
Resolution:
Yes, 672/692REx required the 788-12/18 door loop or at least 4 wire electric hinge or Von Duprin EPT10.In addition, because they are surface mounted and do not affect the rating of t...:
Which Allegion company handles the programming for the PRO 993?
Resolution:
Schlage Electronics:
What is the mounting difference between a 2010 closer and a 2030 closer?
Resolution:
The 2010 and 2030 closer are not the same. The 2010 Series closer uses the (larger) 4010 cylinder which requires a 4" minimum frame tube to mount in. The 2030 uses the (narrow) "Pacer" cylinder...:
Customer has existing EL99 x CM993HW x PS873-2, They now want to add a pushbutton to allow entry from outside. How does it get wired?
Resolution:
Push button gets connected to the input of the PS873-2 power supply (SC & I1).:
Von Duprin Chexit device keeps going into alarm by itself.
Resolution:
Chexit devices shipped with solenoid prior to 8-24-2015. 1. When Chexit device is set for more than zero second rearm time (factory setting is 10 second rearm time) and device goes...:
What is the part number for the former F588 from Monarch?
Resolution:
The top latch for a Fire rated surface vertical rod device is part #650375-00 which replaced the old part #F588.:
What is the part number for the 4642 cylinder only?
Resolution:
The 4600 cylinder only part numbers are: 4640 Series -- 4642-3971 4630 Series -- 4631-3971 The 4642-3971 is for push side only and the 4631-3971 is for pull side only.:
Can you power an electric strike or maglock from the 9500 Series Senior Swing?
Resolution:
An electric strike or maglock (24 volt only) can be wired to a Senior Swing 2800/9500 series operator using the P10 Lock Interface cable.For Current Sr Swing control boxes with ID# 72940 on th...:
What is a CLN80?
Resolution:
The Command Access electrified version of the Schlage ND series cylindrical lock line allows for remote keyless access and egress control for standard commercial use applications where security and...:
«