Question
Answer
Are the 6000 series strikes field selectable for 12 or 24 VDC?
Resolution:
All 6000 series electric strike would require the solenoid be replaced to convert from one voltage to the other.:
Can you change the handing of the 2090 in the field?
Resolution:
The 2090 is handed and is not reversible.:
What is a setup key?
Resolution:
A setup key is an Everest key that has had the upper half of the blade removed. A setup key is an Everest key that has had the upper half of the key blade removed. See picture. A ...:
What is the difference between the 38-031 and 38-032 adapters?
Resolution:
38-031 is a light gauge ring for use under a cylinder, diameter is 2 1/2". The 38-031 when used under each cylinder on the B252 to allow the lock to be used on a 2-1/8" bore.Images of the plates lo...:
Can electrified hinges be used on QEL devices?
Resolution:
The electrified hinge can be used on QEL exit devices.:
What is the dimension of the A30775-000-00 thin door spacer for T series?
Resolution:
A30775-000-00 is the thin door shim kit (1-3/8 > 1-3/4") used for Falcon T lock containing two 030737-000 shims, one for each side.:
Is the power to the Von Duprin potted module polarized?
Resolution:
The power to the Von Duprin potted module also called potted circuit breaker is non polarized.:
What is the part number for QEL94/95 inpact conversion kit?
Resolution:
The part will be configured as CONVERT.XXXX part numbers. The customer need to specify the following criteria. Required: Series 94 or 95, Fire or Panic , 3 feet/4feet or 2 feet 6 inches/2 feet...:
Can you use a Senior swing with a balance door?
Resolution:
Push side only, has to have a 12 1/4 spindle center. Single door minimum is 43" and a double door is a 84" door minimum.:
Are the 6000 electric strikes UL listed for fire rated openings?
Resolution:
Only fail secure 6000 series electric strikes are UL listed for fire rated openings. Door height is limited to 8' per UL. See electric strike catalog for 9854 mullion application defining that 8' h...:
«