Why are lead lined frames used?
Resolution:
Lead lined frames are intended for use in the X-ray Room locations in Health Care facilities. Frames are provided by Steelcraft prepped as follows: Frames are supplied knock-down (KD). Fram...:
Why does Schlage Express tell me I have to program all doors at my site?
Resolution:
Time zones are assigned to locks in a system not to specific users – that is why all doors are reported to need programming … All of the locks at a site will need to know about the new...:
Why does the Schlage button light up “Green” when I open the door?
Resolution:
When unlocking the CO200 door by mechanical key override, the green led will be continuously ON until the key is released. This will occur after firmware CO.A.6 (or later) has been installed int...:
Is a 4 wire transfer hinge enough for a LX-RX-EL device?
Resolution:
This application requires at least six wire hinge, two for RX, two for LX and two or four for EL device. You will need an eight wire hinge and double up the EL wires.:
What is maximum width, height and weight for IVES butt hinges?
Resolution:
Butt hinges can be used on doors up to 4' wide and 200 pounds. There is no maximum door height. However, an additional hinge must be installed every 30" when exceeding a 7' d...:
Is the B664 deadbolt available with an interchangeable core?
Resolution:
The B664 deadbolt is not available with an interchangeable core. The available cylinder options for the B664 are: P6: 6-Pin Cylinder P: 6-Pin Cylinder Keyed 5 Z: Evere...:
What is the part number for 98/9927-F top latch less cover?
Resolution:
The part number for 98/9927/F top latch less cover is 050400.:
Is the 224HD available with hospital tip?
Resolution:
The HT (hospital tip) option was discontinued in October of 2017. The hospital tip option is available on the 224XY hinges.:
Can you use a CD conversion kit on a 22 device?
Resolution:
Cylinder dogging CD is not available with 22 series exit device.:
What is the control key bitting for 0 bitted small format interchangeable cores?
Resolution:
For all Schlage and Falcon small format interchangeable cores shipped from the factory 0-bitted, the control key will be cut to all 4's (as of June 25th, 2022 Falcon has discontinued the 0-bit...:
«