The plug on my CIP Module is broken
Resolution:
The miniature banana plug on the module can be ordered directly from the part manufacture (Pomona Electronics, Sales: 900-490-2361 part number model #4513) or from (Digi-Key part number 501-1425-ND).:
How do you convert the Von Duprin 98/99 Rim or Vertical Rod/Cable device from NL (nightlatch) to L (classroom) function?
Resolution:
To convert the 99 rim or vertical rod/cable device from NL to L function, remove the NL drive screw on the center case assembly. See attached instructions: 99 device function for trim. Y...:
What is the difference between the Von Duprin 1439 strike and the 299 strike when using the 33A/35A rim device?
Resolution:
The Von Duprin 1439 strike is designed to be used on a blade stop frame and is 1/2" in height. The 299 strike is normally used on the stop of a frame and is 13/16" in height. :
Why does my Schlage Express get hung up when trying to view Audits
Resolution:
:
Can the L9050 be converted to an L9056?
Resolution:
In order to change functions between an L9050 and an L9056 a new lock body would be needed. The lock body part number for an L9050 is L283-133. The lock body part n...:
Is the LM9000 certified for in-swing and out-swing applications?
Resolution:
The LM9000 is only certified outswing when used for tornado applications.:
Will the 61-509 D271 emergency key operate the D871?
Resolution:
The 61-509 emergency release tool used on the Schlage B571 and Falcon D271 can be used to operate the discontinued Falcon D871 indicator deadbolt.:
Why are lead lined frames used?
Resolution:
Lead lined frames are intended for use in the X-ray Room locations in Health Care facilities. Frames are provided by Steelcraft prepped as follows: Frames are supplied knock-down (KD). Fram...:
Why does Schlage Express tell me I have to program all doors at my site?
Resolution:
Time zones are assigned to locks in a system not to specific users – that is why all doors are reported to need programming … All of the locks at a site will need to know about the new...:
Why does the Schlage button light up “Green” when I open the door?
Resolution:
When unlocking the CO200 door by mechanical key override, the green led will be continuously ON until the key is released. This will occur after firmware CO.A.6 (or later) has been installed int...:
«