Question
Answer
What cores are available for Republic bullet resistant doors?
Resolution:
Polystyrene Levels 1Polystyrene with armor plating Levels 2-3Mineral wool or fiberglass batting with armor plating Levels 4-8:
What is the bottom channel for Republic bullet resistant doors?
Resolution:
Bottom Channel is an inverted 16 gauge steel channel, projection welded at a maximum 2-1/2" on center:
What is the top channel for Republic bullet resistant doors?
Resolution:
Top Channel is a flush 16 gauge channel, projection welded at a maximum 2-1/2" on center:
Are the jamb bracket screws for the Glynn Johnson overheads self drilling/self tapping?
Resolution:
The jamb bracket screws for the Glynn Johnson overheads are not self drilling/self tapping as noted in the respective templates/installation instructions available in Find Product Templates | Alleg...:
Is a lock guard need when paired with a rim exit device
Resolution:
Typically a lock guard is not needed when paired with a rim exit device because the latch is normally behind the door and thus not accessible to attack from the exterior/pull side of the door.:
Can a Vertical Rod Exit Device be installed with the bottom rod only (no top rod)?
Resolution:
Vertical Rod Exit Devices are not designed or tested Less Top Rod. The standard top latches of Vertical Rod Exit Devices are designed to catch in the retracted position while the door is open....:
What thru bolts are used on L locks with N Escutcheon trim and Gen 2 Indicator on the outside?
Resolution:
For the Schlage L series mortise locks with N escutcheon trim and with Generation 2 (Gen2) indicator on the outside, the thru bolts are the same as on non-indicator trim. K510-389 - thru bolt...:
What is the distance from the HL6-9000 cover to the edge of the door when mounted horizontally?
Resolution:
The distance from the edge of the door to the HL6-9000 cover when mounted horizontally is 5/8":
Does the use of a thimble strike invalidate the UL listing on the B500 series?
Resolution:
The 10-064 thimble strike has been tested and certified for use with the B500 series UL listed deadbolts. Using the thimble strike does not invalidate the UL listing.:
What is the part number for the LM9210 or LM9225 lock body only?
Resolution:
The LM9210 and LM9225 functions use the same lock body part number. The part number is: 24759599 for the lock body only.:
«