Where is the cross reference list for PS800 to PS900 series power supplies?

The following Legacy information is important to understand before cross referencing power supplies:

  1. PS-900 option boards will NOT install onto the legacy power supplies. This includes battery and fire alarm boards.
  2. Legacy option boards (873-4TD, DCM, RCM, etc.) will NOT install onto the PS-900 supplies.
  3. All option boards now switch positive voltage.
  4. If a customer needs to replace a legacy power supply consisting of the following options, then the replacement supply can be built from the cross reference table.
    • No option boards
    • Fire alarm or battery only
    • 2Q only (with or without fire or battery)
    • 871-2 only (with or without fire or battery)
  5. If a customer needs to replace a legacy power supply which contains logic boards then consult Technical Services to confirm that correct replacement hardware is specified.
  6. IMPORTANT: The enclosure sizes are different.
    • PS800 series power supplies are 10" H x 12.5" W x 5" D
    • PS900 series power supplies are 14" H x 12" W x 4" D.
After determining the legacy power supply, refer to the PS-900 Cross-Reference Guide

Von Duprin PS914-4RL power supply replaces the PS873-4TD.


DISCLAIMER:

INFORMATION PROVIDED THROUGH THIS SITE IS PROVIDED TO YOU AS IS WITHOUT ANY EXPRESS REPRESENTATIONS OR WARRANTIES OF ANY KIND, AND WE MAKE NO REPRESENTATION OR WARRANTY THAT THIS SITE(OR ANY INFORMATION PROVIDED IN RESPONSE TO YOUR INQUIRY), WILL BE ACCURATE, COMPLETE, OR ERROR-FREE.

YOU AGREE THAT YOU MUST EVALUATE ALL INFORMATION AND RESPONSES, AND THAT YOU BEAR ALL RISKS ASSOCIATED WITH, THE USE OF THIS SITE, INCLUDING ANY RELIANCE ON THE ACCURACY,COMPLETENESS, OR USEFULNESS OF ANY INFORMATION OR MATERIALS MADE AVAILABLE THROUGH THIS SITE.

Other users ask