CT5000 Construction Mode

Creating a Master Construction Credential -

From first power up or after clearing memory:

  1. Remove the CT5000 lid.
  2. Press and hold the Schlage button.
  3. Present a credential to the reader within 5 seconds of pressing the Schlage button.
  4. The DEBUG LED and the reader's LED will blink green 5 times.
  5. This credential becomes the Master Construction Credential


NOTE: If the credential is not presented within 5 seconds, timeout will occur. Repeat steps 2-5 above.

After creating a Master Construction Credential, Normal Access Construction Credentials can be created.

To create an access credential:

  1. Present the Master Construction Credential to the reader.
  2. The DEBUG LED and the reader’s LED will light green for 20 seconds.
  3. Present the credential to be programmed within 20 seconds.
  4. The DEBUG LED and the reader’s LED will blink green 5 times.

To end construction mode, either:

  • Reset CT5000/Clear Memory
  • Program CT5000 with HHD



DISCLAIMER: