power supply for ma series
”
RELATED FAQS
Question
Answer
Will one PS902 power supply run two Von Duprin exit alarm ALK'S?
Resolution:
PS902:
What current should an AD-Series or CO-Series lockset draw while in its low power "Sleep" mode?
Resolution:
Use a multi-meter in series with the batteries to measure battery current. Be sure your multi-meter can accurately measure very low current, in the micro-amp range. See the attached Technical Not...:
Where are the Data sheets or Installation Instructions for the 900 series Power Supplies?
Resolution:
Data sheets and installation instructions for 900 series power supplies are available at http://us.allegion.com/Services/TechSupport/Pages/home.aspx?ps=Electronic%20Security&pc=Electronic%...:
Can Battery Backup (BB) be added to a PS900 series power supply in the field?
Resolution:
Battery backup can be added to the PS900 series power supplies. Order the 900-BBK to get the battery backup board and batteries for field installation.:
Upgrading any AD-Series lockset to an AD300 - power restrictions
Resolution:
Connect 12VDC or 24VDC power supply to the AD300 lock before attempting HHD communication.:
Where is the cross reference list for PS800 to PS900 series power supplies?
Resolution:
Von Duprin PS914-4RL power supply replaces the PS873-4TD.:
Can the new 900-2Q option board be used with an old Von Duprin PS873 power supply?
Resolution:
The PS900 power supplies will only accept the 900-XX option boards.:
What are the dimensions of the MA Series escutcheon?
Resolution:
The Falcon MA Series escutcheon is roughly 8.15" tall x 2.28" wide x 0.37" thick.:
Why is the battery draining so quickly on an AD-Series lock with a Keypad ONLY (KP) credential reader?
Resolution:
A Technical Note has been generated to document one method of measuring battery current. See the attachment HERE.:
When would you use the 900-4R option board in a 900 series power supply?
Resolution:
The 900-4R is used with PS900 series power supplies. The 900-4R has four independent outputs and inputs with no time delay. You can use any of these outputs with electrified hardware including EL...:
Why does the PS900 power supply not provide any DC output when AC power light is on?
Resolution:
The following items may cause the PS900 series power supply to have no DC output voltage. 1. If the DC voltage selection jumper is missing, the power supply will not provide any D...:
What drains the AA batteries on an AD-Series lock?
Resolution:
Causes for AA battery drain in AD-Series LOCKS Possible Cause Fix/Corrective Action 1) One the four (or eight) AA was inserted reversed and the rese...:
What power supply replaces the PS 873 - 4TD?
Resolution:
Option Board Von Duprin PS914 Schlage PS902, PS904, PS906 900-2RS Yes No 900-2Q ...:
Are the batteries for the PS 914 BBK the same as the ones from the 873 BB?
Resolution:
The battery for the PS873 and PS914 are the same, 7AH sealed Lead Acid battery.:
What is the part number for the lever return spring for the MA lock?
Resolution:
Lever assemblies part numbers are found in the Pricebook. Note they are handed.:
What is the low battery threshold for the AD and CO Locks?
Resolution:
CO200 & CO250 Disable coin cell Nuisance delay and blink, With CO.A.7 and SUS 4.10.2 or newer for CO200 and CO250, you can use the SUS/HHD, under Lock Properties, Edit, to de-select, DISABLE, t...:
What replaces the Von Duprin PS873 power supply?
Resolution:
Option Board Von Duprin PS914 Schlage PS902, PS904, PS906 900-2RS Yes No 900-2Q ...:
What are the amperage and power supply requirements for the Von Duprin Chexit (CX) devices?
Resolution:
Chexit motor driven devices shipped after 8-24-2015:You can use 1 Chexit device with PS902, 3 Chexit devices with PS904, and 4 Chexit devices with PS914 or PS906 power supplies with proper gau...:
Are the M and MA locks compatible?
Resolution:
No parts are compatible between the Falcon MA-Series and the obsolete Falcon M-Series.:
How many Von Duprin ALK's can be powered off a PS900 series power supply?
Resolution:
The Von Duprin exit alarm ALK draws about .25 amp. PS902 power supply powers up to 8 exit alarm ALK. PS904/914 powers up to 16 exit alarm ALK. PS906 powers up to 24 exit alarm ALK. :
What is the Buy American Act (BAA)?
Resolution:
To obtain product certification forms:Download the BAA Catalog on the Allegion website Complete the information requested in the the BAA Catalog with a detailed copy of the prod...:
Will the Von Duprin 6210 electric strike operate with the MA series locks?
Resolution:
The Von Duprin 6210 electric strike was designed for retrofit applications and will not work with the Falcon MA series lock when strike and lock body are mounted at standard locations (centerline o...:
Would the 900-4R option board control EL devices in a PS914?
Resolution:
The 900-4R is used with PS900 series power supplies and has four independent outputs and inputs with no time delay. You can use any of these outputs with electrified hardware including EL devices a...:
What power supply is required to operate the 6000 series electric strike?
Resolution:
Option boards are not required with PS900 series power supplies when using electric strikes. See the list of options below. The PS902 would power up to 5 electric strikes at 24VDC or&n...:
Where can I order a Hand Held Device (HHD), Pidion, accessories?
Resolution:
Warranty on the HHD is one (1) year from date of purchase. The battery for the HHD (Bluebird Pidion) is covered under warranty. However, as the batteries are not ...:
What non IC cam is offered by Schlage to work in a Falcon MA lock?
Resolution:
Price Book 72A List Price $8.10:
Are the legacy Von Duprin PS873 and the current PS900 power supplies filtered and regulated?
Resolution:
The Von Duprin PS873 and PS900 series power supplies are filtered and regulated.:
How do I program my device?
Resolution:
The programming processes for Allegion devices can be both product and features specific. Some products programming processes are electronic in nature, others are physical in nature. &nb...:
Can the AD-Series and CO-Series magnetic card credential readers be set to read data from different magnetic card tracks?
Resolution:
Customers will need to use the Schlage Utility Software (SUS) on the HHD lock programming device to set the desired magnetic track to be read for access control, if not using default Track 2&n...:
Does Falcon have a breakaway lever trim feature on mortise locks?
Resolution:
The MA lock does not have Vandlgard or a breakaway trim feature, however, the lever spindle on the MA lock will shear if too much force is applied in order to prevent internal lock damage and resis...: