Answer
What is the rough opening in walls for frame installations?
Resolution:
For DW, K three sided frames and four sided borrowed light frames: Three sided frame = door opening width (order size) plus 1 1/2" minimum to 2" maximum and the door opening hei...:
What is the ANSI recommendation for the distance between the actuator and the door opening?
Resolution:
Always check the most current revision of the ANSI A156.19 standard for recommendation or requirement of the location of a Knowing Act switch. 2019 ANSI A156.19 states the requirement of the ...:
Are Steelcraft doors and/or frames fire rated?
Resolution:
Yes, Steelcraft doors and/or frames are available and can carry a UL, WH or FM label. The type of fire label (UL, WH or FM) is dictated by the specifications and local building code. Doors ...:
What could cause a 9100 Series Benchmark operator not to open when the actuator is pushed?
Resolution:
If the 9100 Series Benchmark operator does not open when the actuator is pushed: Verify the unit has 120 volts applied to it. Verify the the power light on the control box is on. If not, check ...:
What is the max rating available on an full glass (FG) door?
Resolution:
A UL 20 minute fire rating is the maximum fire rating for a Full Glass (FG) door design. A14-Series door construction: Max fire rating is 20 minute. UL label only FG must use Over-Lapping Stee...:
How many P & D (Pierce and Dimple) holes are in a frame?
Resolution:
The following are quantities of EMA anchors (pierce and dimples) based on range of frame height: Quantity Nominal Frame Height 2 1'...:
Does wall board have to extend into the throat of a fire rated frame?
Resolution:
:
What is clear opening width?
Resolution:
Clear Opening Width for swinging doors is measured (with the door open 90 degree) from the face of door to stop soffit on strike jamb. &nbs...: