double acting fire rated doors

RELATED FAQS

Question
Answer
The Von Duprin 1609 cannot be used on a pair of fire rated doors. We recommend using the Von Duprin fire rated mortise exit device in lieu of the rim device such as the Von Duprin 5575-F,...
Overhead Concealed door closers are used to provide a more aesthetic look to the opening.  Concealed in either the frame or the door Offer the ability to be adjusted to maintain control o...
The LCN 6030 is a Double Acting (or dual action) closer. Requires a "Cased Open Frame" - that means no stops formed in the frame.
Yes, wood doors can be used and installed in most hollow metal frame applications including FE-Series and DE-Series Double Egress frames. Caution - For fire rated applications the wood door manufa...
Door Swing
Non fire rated doors can be furnished with a maximum 3" diameter hole for viewer preparations. Fire rated doors have a 3/4" maximum holes size unless otherwise listed by UL or ITS/WHI. Viewers mus...
Astragals are required on: 3 hour fire rated pairs: Double doors - swinging in the same direction Double Egress - swinging in opposite directions Fire rated Dutch Doors Fire rated 1 3/4" t...
Raceway availability: Optional factory installed raceways are available in doors but are not available in frames. Preparation Info: Steelcraft installs a flexible 1/2" ID steel conduit through the...