co series installation instructions

RELATED FAQS

Question
Answer
This information can be found at the following URL's: AD200/AD250/AD300/AD400 Cylindrical http://w3.securitytechnologies.com/irstdocs/installinstructions/102104 P516-092.pdf
AD200/AD250/AD300/AD400 Mortise http://w3.securitytechnologies.com/irstdocs/installinstructions/102106 P516-093.pdf
AD200/AD250/AD300/AD400 Cylindrical Exit http://w3.securitytechnologies.com/irstdocs/installinstructions/102264 P516-094.pdf
AD200/AD250/AD300/AD400 Mortise Exit http://w3.securitytechnologies.com/irstdocs/installinstructions/102263 P516-095.pdf
CO100/CO200/CO250 Cylindrical http://w3.securitytechnologies.com/irstdocs/installinstructions/104214 P516-266.pdf
CO100/CO200/CO250 Mortise http://w3.securitytechnologies.com/irstdocs/installinstructions/104213 P516-267.pdf
CO-Series Cylindrical Exit http://w3.securitytechnologies.com/irstdocs/installinstructions/102297 P516-268.pdf
CO-Series Mortise Exit http://w3.securitytechnologies.com/irstdocs/installinstructions/102296 P516-269.pdf
 See the attached Technical Note for instructions on saving a "Device Template" FROM a device or loading TO a device, Device Template Tech NoteOn the SUS/HHD go to the LOCK Properties tab, and sele...
For W lock levers, you can choose whether or not to install the mounting posts.  This will also affect how the door is prepped so be sure to determine how you will install the locks befor...
The JD YA6 tailpiece is intentionally designed such that the tailpiece cannot be installed at the same time as the cylinder.  Interchangeable cylinders assume that the lever and taipiece is in...
See the JD Yale Lever installation instruction HERE
On power-up the CO-Series locksets will provide 5 quick RED Schlage Button flashes and 5 quick beeps to indicate that the electronics (credential reader) has been changed.  In order to recover...
When/If the electronics (Credential Reader) changed on a CO-Series lockset, the lock will respond with 3 RED Schlage button flashes and 3 beeps for any key press or credential presentation.&nb...
CO Reader Modules cannot be replaced by Reader Modules with a different credential type; for example, a magnetic swipe credential reader cannot be replaced with a proximity credential rea...
A Credential Reader MAY be replaced with another Credential Reader of the same type; however, a Factory Default Reset must be performed before the lock will function properly.
The minimum recommended Stile measurement is 5” to allow proper mounting of the AD and CO series locks.
You will need to use Special Template ST-3448, allows you to mount the 4041EDA and a GJ81 Series (814-816).
The 4110 series closer is installed on a flush transom frame using the -419 flush panel adapter.
The 5100 strike details are listed below: Only operates with 12VDC or 24VDC power supply. Will not operate with AC transformer. 12 or 24VAC can be converted to 12/24VDC using Von Duprin SO12 o...