Why would a 4600 not open a full 90 degrees?
Resolution:
A 4600 (4630/4640) not opening to a full 90 degrees could be caused by a couple things: The Opening Force could be set too low. Try increasing the opening force adjustment on the controller a 1/...:
What causes am ME Series closer to creep shut (creeper)?
Resolution:
If an ME Series closer creeps shut or will not hold open, Verify proper voltage is being supplied to the closer, if correct Check the on/off switch. Verify the voltage on the 2 pin co...:
Is the MA lock available with the RX feature?
Resolution:
The MA RX features a single switch within the chassis that will monitor both the inside and outside knob/lever. The switch is only available as Normally Open (NO).:
Von Duprin Chexit device keeps going into alarm by itself.
Resolution:
Chexit devices shipped with motor after 8-24-2015. 1. When Chexit device is set for more than zero second rearm time (factory setting is 10 second rearm time) and device goes into alarm immediatel...:
Why does the arm of my 4110 EDA touch the door when it is closed?
Resolution:
If the closer arm is touching the door, it is because the arm or the closer body is not templated correctly. Confirm dimensions are taken from the proper location and make corrections if needed. :
What degree of lever rotation is required to operate the RX feature?
Resolution:
The RX switch is activated at approximately 18 degrees of lever rotation. :
What are the 3 wires on the Falcon AE switch?
Resolution:
For 24/25 devices per instructions : Violet - Normally Open Black - Common Gray - Normally Closed: