wiring diagram auto operator

RELATED FAQS

Question
Answer
The 8310-865 RF receiver contacts (N.O. and COM) would connect to terminals 15 & 17 (the alternate action input) on the 4600 operator. The first activation would open the door, the second...
 EL devices are wired to the Senior Swing, using the P10 (761465) cable.  Connect the "GRAY" wire to the SC terminal on the 900-2RS card in the Von Duprin Power Supply and the "VIOLET" wire to the ...
The Benchmark III control has a 24VDC, 2.5 amp power supply, and built in relay for controlling electric strikes or other accessories less than 2.5 amps current load. For a fail secure strike, r...
The 8310-865 RF receiver connection to the Falcon 8200 operator are: RED and BLACK power wires on the receiver connect to the 12V AC terminals on the Falcon operator. The WHITE wire from the COM t...
See Point to Point wiring diagram here.
The "common" of all the actuator switches will connect to terminal 10. The N.O. (normally open contact) will connect to Terminal 5, 6, 7 or 8 depending on which control box is used and the function...
The 4630/4640 operator can accept any ( normally open / dry contact) actuator - hardwired or wireless.  LCN Wireless actuators require the use of the 8310-865 RF receiver.The 8310-856 RF ...
The 4630/4630 operator has a 12 VDC and 24 VDC output that can power an electric strike or maglock. The wiring diagrams are shown on page 14 of the installation instructions (attached). 4600 Insta...
The 4600 Series operator has both a 12VDC and 24VDC output rated at 1A (combined load) to power strikes, maglocks, and other devices, but an EL device "always" has to have a separate PS914-2RS Seri...
 Pneumatic Automatic Operators are used in areas where electrically operated devices are not convenient or permitted.  Consists of a modified, heavy-duty door closer for manual oper...
Wiring and Riser diagrams can be accessed at:Common wiring diagrams can be accessed at:  http://kc.allegion.com/.   Click on the "Common Wiring Diagram" link.To request a custom wiri...
Partner Solution: Integrated Access Control Solution with AD-300 Hardwired, AD-400 Wireless Locks and Avigilon RedCloud Access Control System.See the download cut sheet at:Avigilon Red Cloud&n...
Reference The 914 Installation instructions.
The following common wiring diagrams are available:One Single Door with Panic BarElectric Latch Retraction, with Auto OperatorDelayed egress - Fire Rated ApplicationAuto Operator and actuatorElectr...
Electronic Protocols:Access Control Door with electric trimAccess Control with electric strike Access control with electric strike and LCN 4600 automatic operatorAccess Control with remote Loc...
As of June 2011 the electrified T locks can support 12 or 24 Volts.  You do not need to specify 12 or 24 when ordering since the solenoid is capable of either voltage out of the...
Prior to June 2011 the T lock only supported 24V and the electrical requirements were as follows: 0.185 amp @ 24VDC Wire Gage 22 AWG See wiring diagram here - (Previous 2 wire versi...
 The 10-042 is an electric strike used for cylindrical and tubular latch sets.  VOLTAGE  24 VAC  12 VDC  AMPERAGE  0.74A 0.33A   FREQUENCY  60 HZ ...
Applies to L9090EL/EU, L9091EL/EU, L9092EL/EU, L9093EL/EU, L9094EL/EU, L9095EL/EUThe Schlage electrified L-Series wiring diagram can be found here and the re...
Applies to L9080EL/EU. L9082EL/EU (Discontinued)The Schlage electrified L-Series wiring diagram can be found here and the requirements are listed below. 24VAC or 24VDC (maximum 26V, ...
Click here to show the differences of an installed lockcase between the L9090, L9091, L9092, L9093, L9094, L9095 EL/EU and the L9080 EL/EU
The MA lock can be specified in a 12 or 24V DC configuration (default is 12V). Additionally, an AC power source may be used as long as a rectifier is installed in the circuit (not provided). He...
For additional details and a wiring diagram see the MA service manual page on electrical requirements here.
The Senior Swing control box has a built in (programmable) relay output for connection to a Fail Safe/Fail Secure electric strike/maglock or to an EL Device power supply.
The 8310-877 Bodyguard Safety Sensor attaches (plugs in) to the P1 connector on the Senior Swing controller. The 8310-846 (761462-00) wiring harness "included" with the 8310-877 safety sensor is us...