Reference The 914 Installation instructions.
The potted circuit breaker for the Von Duprin EL device does the switching from the 16 amp pull coil on the solenoid to the .33 amp holding coil of the solenoid.
The 4600 Series operator has both a 12VDC and 24VDC output rated at 1A (combined load) to power strikes, maglocks, and other devices, but an EL device "always" has to have a separate PS914-2RS Seri...
  For Product Shipped Prior to August 2012 using the old (black) potted module: a.       0-100 ft 14 gauge wire b.      0-200 ft 12...
 
The power to the Von Duprin potted module also called potted circuit breaker is non polarized.
For Potted Modules shipped before August of 2012, you can test by applying power to the potted circuit breaker to and if good the following voltages will be seen: 23-24V DC on the gree...