EPT installation guidelines are as follows: Recommended location is 6" below top hinge per template Steelcraft will locate the power transfer prep at the Von Duprin recommended template locati...
BAA/ARRA stand for Buy American Act and American Recovery and Reinvestment Act. A brief description of some of the federal requirements can be found in the BAA Catalog on the Allegion...
Country of Origin (COO) information can be found in the Buy American Act (BAA) brochure.
To obtain product certification forms:Download the BAA Catalog on the Allegion website Complete the information requested in the the BAA Catalog with a detailed copy of the prod...
H-Series doors in single leaf applications with only mortise locks meet the FBC / NOA Zone 4 requirements? 3070 max flush outswing applications Zone 4 requires 120 to 170 psf.
For wiring information on the DC-104 data converter for Biometric FingerKey products refer to  DC-104 technical note
Steelcraft have tested different types of doors and frame assemblies using Zero International gasket seals for the various STC ratings. Tests are in accordance to ASTM...
Frames can be installed either KD (knock down) or welded to receive the STC rating.
Steelcraft borrowed light frames are not listed/tested. Check with the glass manufacture if they are listed and with what type of framing used.
Sound seals are required. Zero International Gasket Notes: Perimeter Seals – Zero #475 applies to the stop of the head and jambs. Door bottom – Zero #367, surface applied. Threshold ...
Allegion order forms are only available to Authorized Distributor Partners.  Authorized Allegion Distributor Partners can view order forms and ordering information by logging onto the “My All...
Steelcraft Paladin PW-Series doors and FP-Series frames meet FEMA Tornado Resistant requirements and have been designed and tested to meet the requirements of FEMA 361 guidelines and ANSI ICC500. ...
A current PDF copy of the Steelcraft Tech Data Manual is available on the Steelcraft website and can be downloaded here. To order a printed copy of the Steelcraft Tech Data Manual contact the Cust...
Insulclad® entrance door systems are commercial aluminum entrance systems manufactured by Alcoa/Kawneer. Door panels include a layer (1/4" or 1/2" thick) of material added to the push side of ...
Steelcraft doors and/or frames do not contain any asbestos. Steelcraft did use asbestos in the following products: Steelcraft S16-Series stile and rail door with flush panel and UL fire door l...
Steelcraft frames and doors are furnished with a high grade, low gloss, baked-on prime paint that provides the best possible protection against corrosion, abrasion and weather, and is an excellent ...
"5, 10 and equal" Hinge Spacing: The industry terminology which usually refers to the Custom (NAAMM/HMMA) Door hinge locations. This location dictates: Top Hinge - located 5" from the underside ...
STC stands for Sound Transmission Class. An STC (Sound Transmission Class) is a single number rating system derived from measured values of sound transmission loss in accordance with ASTM E90 and...
Steelcraft offer a limited warranty to customers that products will be free from defects in the material and workmanship for a period of 12 months from date of shipment of products.Warranty St...
Job Specific Warranty - If job specific warranty letters or certificates are required, please refer to the Allegion Contact Us web page and request the applicable information.NOTES:F...
All doors are tested in accordance with ASTM C1363 and SDI 113:B18 Series (Steel Stiffeners)     U-Factor = 0.50     R-Value = 2.01B16 Series (Steel Sti...
SDI 114 is no longer published as an SDI performance standard. The new SDI standard for acoustical Performance is SDI 128-09 Steelcraft does offer products that have been tested in accordance wit...