where are valve locations
”
RELATED FAQS
Question
Answer
BACKCHECK SELECTOR VALVE
Resolution:
Valve used to provide proper backcheck location for 4040XP and 4050A parallel arm mounting:
What is the difference between the 4040, 4010, 4020, and 4110 series closers?
Resolution:
4040XP Series (4040 DEL) is a universal closer. *(see note) Non Handed closer. Can be mounted on a RH or LH door. 4041XP - Adjustable size 1 to 6. Can mount push side or pull side of the doo...:
Is there adjustment limits on the regulation valves of LCN manual closers?
Resolution:
The regulation valves are designed to adjust the flow the hydraulic fluid in the closer which regulates the door closing speed through various phases of the closing cycle. The regulation valv...:
How are the solenoid air valves in the 7900 series control boxes marked?
Resolution:
The part number for the solenoid air valve in the 7900 Series control boxes are: 7901/ES7901 - part# 941 - marked A 7902(S)/ES7902(S) - part# 942 - (2 valves) marked A and B 7949/ES7949 - part...:
What is the valve on the back of a 4041/4040XP closer used for?
Resolution:
The valve on the back of a 4041/4040XP closer is a "Back Check Selector Valve" that needs to be turned in on "Parallel Arm" mount applications ONLY. If a 4041/4040XP closer mounted "Top Jamb", or "...:
What is a LCN 1040 or 1050 closer?
Resolution:
The 1040 and 1050 are obsolete closers made in the 50's, 60's, and 70's. The 1260 or 1460 will work as replacements, but they are not direct replacement.:
What would cause a door closer to slam?
Resolution:
There are a few things that can cause a closer to slam. The closer could be adjusted incorrectly. Turn all regulating screws clockwise until they stop. Then open each valve 1 and 1/2 turns. If t...:
What does AVB mean in a closer and which closers are available with this option?
Resolution:
AVB stands for Advanced Variable Backcheck. It is a cylinder option when ordering a 4111 closer (without an ST) that allows backcheck to start at about 45 degrees instead of the normal 75 degrees.T...:
What is the minimum and maximum PSI applied to a 4800 operator?
Resolution:
The pneumatic operators are designed to function with an input air pressure to the 7901/7902 Series control box of 80 (min) 100 (max) PSI, and an output pressure of 60 to 80 PSI to the pneumatic (2...: