Answer
The 2030 closer requires a minimum 1-3/8" top rail on the door for the standard track.  For a top rail less than 1-3/8" and as narrow as 1", you could use the l...
LCN no longer sells, repairs, or has any replacement parts for the track of the old SED units which had a built in detector in the track.    
The SEH is an "electronic holder" (ONLY) that is used to hold open a Fire Rated opening. It requires a door closer to be mounted on the opposite side. It is normally used on an existing opening wit...
It would be unnecessary to use the CNS/Cush arm and the Glynn Johnson overhead devices in the same application, both mechanisms stop the door.
The LCN 4010SE / 4110 SE series are obsolete, and on longer available. They were replaced by the 4040SE series. The 4010SE / 4110 SE track is replaced with the current 4040SE trac...
If a door is being held open by the LCN SEM 7800/1900 magnet or any ME/SE Series Sentronic LCN closer, you can remotely release that door to close by ordering the following parts and wiring per ST ...