Question
Answer
How do you program the 8310-877 safety sensor?
Resolution:
The 8310-877 safety sensor can only be programmed by using the 8310-859 remote. You can not manually program the 8310-877 safety sensor. However, you only need (1) 8310-859 remote to program any nu...:
How is the 8310-877 wired to the 4600 (4630 4640) operator?
Resolution:
The 8310-877 comes with a 6 wire cable. You have to cut the connectors off both ends and hardwire it to the 4600 operator as follows: The 6 wire cable connections to the 7 pin connector in the 8310...:
Where does the 8310-877 safety sensor attach to the Senior Swing controller?
Resolution:
The 8310-877 Bodyguard Safety Sensor attaches (plugs in) to the P1 connector on the Senior Swing controller. The 8310-846 (761462-00) wiring harness "included" with the 8310-877 safety sensor is us...:
What are Hold Open Closers & Magnets?
Resolution:
Hold Open Closers & Magnets (Fire/Life safety products) provide a wide range of solutions. Single or multi-point hold open closers Utilize an electromechanical closer. Hold the door o...:
What are security jamb anchors?
Resolution:
Security anchors are used in DW/K frames located directly above or below strike preparation on door side of frame. Because there are only two points of anchoring, the compression anchor near the ...:
Support for Sitemaster software.
Resolution:
Sitemaster support is handled by Matrix Security and all inquiries are directed to them.An FAQ for Sitemaster can be found hereTheir support line is 1-800-622-4893Videos and demo downloads ava...:
Can a magnet, or sentronic device, be released and close the door from a button at a desk?
Resolution:
If a door is being held open by the LCN SEM 7800/1900 magnet or any ME/SE Series Sentronic LCN closer, you can remotely release that door to close by ordering the following parts and wiri...:
Can you have a security stud hinge with a TW option?
Resolution:
The Security Stud and TW4/8 (through wire) options are in the same location on a hinge and cannot be ordered together.:
Is the Falcon T381 a true classroom security function?
Resolution:
T381 Classroom Security Lock is not a "true" classroom security / Intruder lock function. The T381 is classified as a ANSI/BHMA F88 function: Defined as Grade 1, Apartment, Exit or Public Toil...:
What is a mortise lock?
Resolution:
Mortise Locks: a lockset where the case is designed to fit in a mortise in the edge of a door Medium, high to extra heavy duty Commercial, multi-family and institutional applications Pros - ...:
How do I wire an EL device to normally hold open the latch and release it during a fire alarm?
Resolution:
Use a normally closed fire alarm as the input to the power supply option board (PS873-2 or PS914-2RS), this will hold the latch retracted. During a fire alarm, the contact will open, dropping...:
Why is the electric E996L-FSE trim used with a Chexit CX99 exit device?
Resolution:
The E996L-FSE trim is needed if the application requires fail-secure operation from the trim side of the opening. When power is out on Chexit device, E996L-FSE trim will remain locked to ...:
Can an EL device be ordered Fail Secure?
Resolution: