When the battery is depleted to 6.5 volts (i.e., the Low Battery Nuisance Delay
begins), a valid Normal credential will operate the lock at least 500 times before Critical Battery Level
lockout occ...
Information on low battery threshold and nuisance delay is noted below: New firmware now has improved levels.
- These are approximate values/levels which change with measurement meters and measure...
AD400/AD200/AD250 After ADFwPkg 2.17.0 - June 2011
4 Battery Holder
New batteries = 6.2 VDC
Low battery threshold is 4.7 VDC for SM & MT - and 3.7 VDC for MAG and PROX (USB stops working at 4...
AD400/AD200/AD250 After ADFwPkg 2.17.0 - June 2011
8 Battery Holder
New batteries = 12.4 VDC
Low battery threshold is 7.2 VDC
Critical battery threshold is 6.9 VDC
Coin cell = new/...
CO2004 Battery Holder (ONLY)
New batteries = 6.2 VDC
Low battery threshold is 4.2 VDC
Critical battery threshold is 3.9 VDC
Coin cell = new/full is 3.0 VDC, low is 2.8 VDC
CO2504 Battery Holder (ONLY)
New batteries = 6.2 VDC
Low battery threshold is 4.2 VDC
Critical battery threshold is 3.9 VDC
Coin cell = new/full is 3.0 VDC, low is 2.8 VDC
CO200 & CO250 Disable coin cell Nuisance delay and blink,
With CO.A.7 and SUS 4.10.2 or newer for CO200 and CO250, you can use the SUS/HHD, under Lock Properties, Edit, to de-select, DISABLE, t...
The AD lock battery pack type can be changed following this procedure:1. Disconnect the existing battery pack2. Depress and hold the SCHLAGE button for a few seconds to drain off any residual...
The SUS can change the logic polarity of the AD400/WRI400 PIM400-TD2 outputs RTX, DPS, TROUBLE, and REN from LOCK/DOOR PROPERTIES Edit tab. You can change High to Low to High using the ed...
These SUS settings have no effect when the AD400 is linked to a PIM400-485; because the PIM400-485 reports the logic status with RSI-485 commands and not logic levels. The settings are gray...