WHAT IS EDA VS CUSH

RELATED FAQS

Question
Answer
EDA ARM - The EDA arm is a heavy duty parallel arm mount.  The degree of door opening is determined by the template used for mounting. EDA arm closers can only be mounted as a Push Side parallel ar...
Cam Lift hinges can only be used with LCN door closers that have a "Regular" style arm.     Manual Closers: Maximum lift dimension is 3/4". Can not be use EDA, CUSH, or Track Arm door closers...
The 4110-18, and 4110-18 CUSH  drop plates are identical. The difference between a 4110 EDA, and a 4110 CUSH is the templating on the door. That is why you order them differently, to...
The dead stop post would need to be removed and the 4040/4040XP EDA mounting template for 180° would be followed.
ST-3195 is used to obtain the old style EDA or Cush arms which were assembled with threaded studs so that you could take apart the arm assemblies. Our current standard EDA and Cush arms are rivet...
Yes, as long as you stay with the like style arm.  Example: replace an RW/PA with HW/PA, replace an EDA with HEDA, or replace a CUSH with HCUSH.
The 419 panel adaptor is the replacement for both the obsolete 145 shoe, and 418 panel bracket (both were made obsolete in 2009). The 419 panel adaptor is 4" wide, 2" tall, and projects 3". ST-069...
The 4040 XP CUSH/EDA can be mounted on a Flush Transom frame by using a -419 Flush Panel adapter.
4040XP Series (4040 DEL) is a universal closer. *(see note) Non Handed closer. Can be mounted on a RH or LH door. 4041XP - Adjustable size 1 to 6. Can mount push side or pull side of the doo...
The 4040/4040XP closer mountings have the following maximum opening degree templating: The 4040/4040XP PA "Regular Arm" mount will allow for 180° max. opening. The 4040/4040...