what does an rx device look like?

RELATED FAQS

Question
Answer
You must replace the entire RX switch assembly for Chexit devices shipped after 8-24-2015 with motor driven.
The part number for the RX switch pig tail (black plug) with two orange wires only for Chexit devices shipped prior to 8-24-2015 with solenoid driven is 991338-00. 
The RX switch can be installed at the factory when device is ordered or in the field with part# 650359-00. Installation instructions here will show how the RX swi...
Chexit devices shipped after 8-24-2015 with motor driven:If two pin REX connector cable is plugged into the Chexit module and Module REX LED is OFF, the RX switch is defective and needs to be repla...
Chexit devices shipped prior to 8-24-2015 with solenoid driven:If Chexit device goes into alarm with fast flashing red LED after the rearm time, the RX switch may be out of adjustment or defective....
This option is not available.  The 17 & 18 Series devices were discontinued in August 2009 and the new Falcon RX Switch is mounted to a bracket that fits in the pushpad...