Allegion
Terms of Use
Privacy Policy
Frequently Asked Questions
Ask your question
Entering your question as a complete sentence will provide more accurate results than keywords or phrases.
User questions
FAQs
Category List
“
von duprin Electric strikes
”
RELATED FAQS
Question
Answer
Does the Von Duprin 55 Rim device work with the Von Duprin 6111 electric strike?
Resolution:
Yes, but the strike must be ordered "special" and there is a "special" template to verify the 55 device is aligned properly for use with the Von Duprin 6111 electric strike. When ordering the...:
Does Von Duprin offer an electric strike in the 6000 Series that works with a deadbolt only?
Resolution:
Von Duprin offers no such strike. The reason being that the deadbolt would bounce off the strike’s keeper and prevent the door from securing.:
Is the Von Duprin 5100 electric strike intended for use with mortise locks?
Resolution:
No, the Von Duprin 5100 electric strike is only intended for use with cylindrical locks and lever sets. It is NOT intended for use with mortise locks as the strike "pocket" may not be deep en...:
Is there an electric strike for use with 98/9952?
Resolution:
Though not designed for use in exterior applications, the 6111 electric strike will function with the 98/9952 series exit device. Depending on the construction of the gate post, a blade sto...:
Will the 6300 work with the 55 rim?
Resolution:
The Von Duprin 6300 surface mounted electric strike is compatible with 55 rim device.:
What electric strikes are available for Von Duprin rim exit devices?
Resolution:
The 22, 33/35A and 98/99 rim exit devices: The 6111 is the most common electric strike to be used with these devices 6112 and 6113 electric strikes also could be used The 6300 surface mount el...:
What is the device backset when using a 1790 with a 6111 strike?
Resolution:
The Von Duprin 6111 electric strike would work with DOM 1790 device on medium style doors Centerline of the 1790 device mounting screws are located 1 11/16" from face of stop. See d...:
Can the electric strike be used with a vertical rod device on a fire-rated door?
Resolution:
Not for use in fire rated openings.:
Can 24 volts be run to a 12 volt 6000 series electric strike solenoid?
Resolution:
You can't run 24VDC into the 12VDC electric strike, over voltage such as this will cause the solenoid to heat up and damage the solenoid. You must change to a 24V solenoid, part number 050240-00.:
What electric strikes can be used with the Von Duprin aluminum mullions?
Resolution:
Aluminum mullions 5654 or 5754 are not designed to accept any electric strike including 6300 surface mounted electric strike.:
Are the wires on a Von Duprin 6000 series electric strike polarized?
Resolution:
The wires on 6000 series electric strike solenoid are non polarized.:
Will the Von Duprin 6210 electric strike operate with the MA series locks?
Resolution:
The Von Duprin 6210 electric strike was designed for retrofit applications and will not work with the Falcon MA series lock when strike and lock body are mounted at standard locations (centerline o...:
Are the Von Duprin 6000 series electric strikes rated for continuous duty?
Resolution:
All of Von Duprin 6000 series electric strikes have continuous duty solenoids either 12 or 24VDC.:
Can the Von Duprin 5100 electric strike be used on a pair of doors?
Resolution:
The following application information apply to the 5100 electric strike: Can only be used on a single door with a cylindrical lock Can not be used on a pair of doors Can not be used on a mullion:
What questions should be asked to determine which Von Duprin 6000 series electric strike I have?
Resolution:
See Catalog to identify specific model: Von Duprin Electrical Security Products and Accessories Catalog:
What power supply is required to operate the 6000 series electric strike?
Resolution:
Option boards are not required with PS900 series power supplies when using electric strikes. See the list of options below. The PS902 would power up to 5 electric strikes at 24VDC or&n...:
What electric strike can be used on a pair of doors with an L9000 lock?
Resolution:
Von Duprin 6223 electric strike is the most common closed back strike or the 6221 for open back strike on inactive leaf that can be used with Schlage L9000 or Von Duprin 7500 mortise lock.:
How to convert the Von Duprin 6000 series electrical strike from Fail Secure to Fail Safe or Fail Safe to Fail Secure?
Resolution:
Part numbers: FS slider, part # 090591 (Use for all EXCEPT 6211WF/6212WF/6221/6223. See 090798 below) FS slider, part #090798 (Use this slider for FS models 6211W...:
What is dual switch monitoring or DS?
Resolution:
The DS is Dual Monitor Switch for Von Duprin 6100 and 6200 series electric strikes (not 6300 or 6400)DS option cannot be added to a Von Duprin 6000 series electric strikes in the field. It is only ...:
What is the part number for the 6000 series electric strike 24VDC solenoid?
Resolution:
The Von Duprin 6000 series electric strike can be converted by ordering the appropriate kits below. Kits include the solenoid, plunger, spring, and washer. 6000 Series solenoid Kit 1...:
Will the Von Duprin 5654 mullion accept an electric strike?
Resolution:
No, the Von Duprin 5654 aluminum mullion will NOT accept an electric strike. Most electric strikes require 1 1/4" to 1 1/2" of frame "face" to mount flush to the mullion. The 5654 mulli...:
Is there an electric strike that will work with the 2670 Guard X?
Resolution:
The Von Duprin 2670 Guard X does not have a spring loaded latch bolt, it is a dead bolt and will not operate with any electric strikes.:
Will the 6300 electric strike work with the 22 series rim device?
Resolution:
The 6300 surface mounted electric strike can be used with a 22 rim device.:
Is there a monitor switch for the 6300 electric strike?
Resolution:
There are no optional monitor switches available for the 6300 electric strike.:
What electric strike can be used with the 1790?
Resolution:
None of the Von Duprin electric strikes will work in a retrofit application where the normal standard mechanical strike is mounted to the frame because none of them are thin enough to fit in...:
Will the 6300 electric strike work with 88-F or the 88 rim panic?
Resolution:
Von Duprin 6300 electric strike will operate with 88 rim but not 88F fire rated exit devices.:
Can you power a electric strike from the 7900 control boxes?
Resolution:
The power supply output in the 7900 series control box is a 12VDC output, rated at (1/4A) 0.250A. It cannot be used to power a strike or maglock. You need to have a separate power supply for the st...:
Will the 6210 work with the Best 45H? If not is there another electric strike that is compatible.
Resolution:
***The 6210 electric strike was designed to replace mechanical strikes in existing openings when access control is desired.*** Note: The Best 40H series lock is not listed on the 6210 electric s...:
What is the most common practice for running electric power from a frame to the door and hardware?
Resolution:
Electrical hinges or a power transfer units are the most commonly used practices to run electric power to locks and/or strikes. Electric Hinges: Most electric hinges will fit into...:
How can the Von Duprin 4854 mullion be ordered when using the 6300 electric strike?
Resolution:
:
Is a rectifier needed to change AC to DC on Von Duprin 6000 series electric strikes?
Resolution:
The strike will always be DC. By using a SO24 or SO12(rectifiers) you will be able to convert the AC waveform from a transformer to a DC waveform that will be acceptable by the 6000 series strikes.:
Where can Von Duprin 6300 electric strike installation instructions or templates be found?
Resolution:
Von Duprin surface mounted 6300 electric strike paper template and installation instruction are provided with the electric strike. See attachedhttps://us.allegion.com/conte...: