vertical rod dragging

RELATED FAQS

Question
Answer
Required top and bottom rod adjustment. Top rod possibly is adjusted too short and not lifting the rod far enough to engage the latch retention which would cause bottom rod to drag floor ...
One of the following items may cause the EL1490 device to retract then release: Incorrect power supply - Verify you have the PS873-2/4TD or PS914-2RS/4RL power supply. Problems with wire gauge...
One of the following items may cause the EL1690 device to retract then release: Incorrect power supply - Verify you have the PS873-2/4TD or PS914-2RS/4RL power supply. Problems with wire gauge...
Following could cause the bottom latch on 98/9927 exit device to drag. Bottom rod is too long. Adjust bottom rod per instruction sheet 911375. Top latch controls the bottom latch.  ...
There is not enough room for both options as the dogging mechanism in a standard cylinder dogging and the electronics for the EL or QEL options are both located at the end of the base plate. For 9...
To convert the Von Duprin 98/99 Rim or Vertical (Rod or Cable) Exit Device with functional lever (996L-R/V) to act like a rigid lever (996L-NL-R/V) with key over ride follow these steps: R...
 8827 vertical rod device is available for 7 or 8 feet tall door standard. 12", 24", 36" and 48" extension rod kits are available for taller doors (8 feet max on fire rated openings). We do no...