Question
Answer
What is the backset for the Von Duprin WS9827 device when installed on Steelcraft Paladin series door?
Resolution:
The backset is 2 3/4" from edge of door to the center line of the device and strike. The preparation for the WS98/99 strike must be specified when placing order for the frame. :
STRIKE PREP
Resolution:
ASA, ASA-48, ASA-60, ASAR, ASA-SP, ASAV, CYL, CYL-48, CYL-60, CYLR, CYL-SP, CYLV; Prep per Template, SPL:
Factory installed louvers?
Resolution:
Stamped louvers are no longer available from Steelcraft in any door series. Steelcraft discontinued this offering in 2008. Steelcraft will only provide a cutout only in doors for louvers.:
Are EPT preps available on the Paladin Series door?
Resolution:
EPT power transfer preparations are available on the Paladin PW14-Series door and FP14-Series frame. Electrified hinges are available on the Paladin PW14-Series door&...:
What is the minimum rose dimension that can be used with a Steelcraft 61L lock preparation?
Resolution:
The minimum rose that can be used on the 61L (ANSI/BHMA A156.115.18) preparation is 3 7/16".Steelcraft's 61L lock prep (often referred to as the "Squashed Turtle lock prep") is designed for Bored L...:
What is the largest diameter hole that Steelcraft can provide for viewer preps?
Resolution:
Non fire rated doors can be furnished with a maximum 3" diameter hole for viewer preparations.Fire rated doors have a 3/4" maximum holes size unless otherwise listed by UL or ITS/WHI. Viewers must ...:
Where is factory recommendation for location of an EPT?
Resolution:
EPT installation guidelines are as follows: Recommended location is 6" below top hinge per template Steelcraft will locate the power transfer prep at the Von Duprin re...: