Steelcraft N exit device

RELATED FAQS

Question
Answer
Steelcraft L-Series and T-Series doors are available (as an option) factory prepared for the Von Duprin InPact exit device. 
Hardware falling off a door is caused by one or all of the following issues: Field abuse Improper internal reinforcements in the door Improper field preparation The top or bottom rod case can...
Raceway availability: Optional factory installed raceways are available in doors but are not available in frames. Preparation Info: Steelcraft installs a flexible 1/2" ID steel conduit through the...
The conversion kit does not contain a new mechanism case cover plate.  If a cover plate is desired you would need the Fire or Less Dogging Cover Plate for EL conversion kit and panic cover plate fo...
Von Duprin does not offer any of the danmark lever designs by Schlage.
The Falcon 1390 exit device is discontinued and parts are no longer available from the factory. New England Door Closer may still have some older kits and can be contact...
The 5100 electric strikes are for use with cylindrical locks only.  Instead use the following:6211 electric strike is used with mortise lock without deadbolt on a new single door, hollow ...
The old 33/3547 rods will not work with new 33/3547A exit device.
Falcon Monarch XX series trims will work with Monarch 18 series exit devices.
You will need to check with the other manufacturer.  Check the template for the other manufacturer to see if the hole pattern for the trim and the cylinder location would match up.  The VR trim cou...
Following could cause the EL device to pull and drop repeatedly.  Short to ground  on EL wiring.  Incorrect wire gauge used.  For wire run and gauge requirements, click HERE  Wrong power suppl...
To order Von Duprin exit device reference the "Additional information/How to order" section in the Von Duprin catalogs. All Von Duprin device series Catalogs are available on website.
The wires run through the device out to the EPT. See step 7 on page 5 of E996L instructions.
This option is not available as there is no NL cam to directly drive the rods and using a key to lift the heavy stainless, brass or bronze rods would damage the key. 
SD option is available and is also standard with Von Duprin 98/99 rim and vertical rod exit devices but not available with mortise device.
You cannot lock the push side of the exit device as a panic device by design must allow exit.  Any attempt to block an exit is forbidden by code.
Yes, as an option, Steelcraft doors are available with factory prepared for the 98/9949 Concealed Vertical Cable Exit Device. L, B, CE, T and CE-Series doors are available factory prepared Door...