steelcraft door parts

RELATED FAQS

Question
Answer
The 4040(XP) door closer can be used as a temporary replacement in a 4630/4640 operator to provide manual control of the door while the 4630/4640 closer cylinder is being repaired or a replacement ...
The L283-150 is a modified mounting plate to allow a user to only install trim on the inside of the L9000.  For installation and door prep requirements, see the install sheet.  Add...
The part number is: 1461-3071 for the door closer cylinder body.
AL-Series and discontinued D Lever-Series locks use castle nuts to hold the chassis to the spring cages and to keep the chassis positioned in the door. This causes confusion at times when the lock ...
The 4040/4041 closers have been replaced with the 4040XP closer. The 4040XP cylinder replaces all the older versions. There are 2 cylinder "only" option's for the 4040XP series. The 4040XP-3071(...
The SED/MED series closers where discontinued in 2000. The SE or ME series from LCN can be used as replacements to provide a hold open feature, but will not have the smoke detectors ...
The L9000 lock can be ordered for doors greater than 1 3/4" thick.  The allowable door thickness is dependent on the L lock function and how the lock is extended.  All locks for exte...
It is always recommended to point installers to the industry installation manuals which are very comprehensive and are ANSI documents. SDI (Steel Door Institute) installation manual can be found...
Window kits are available for Steelcraft doors as either factory installed or prepared and installed by a distributor. Factory prepared light cutouts are supplied with Dezigner trim as st...
Astragals are required on: 3 hour fire rated pairs: Double doors - swinging in the same direction Double Egress - swinging in opposite directions Fire rated Dutch Doors Fire rated 1 3/4" t...
Dezigner Trim – This unique and patented glass trim has been designed to closely simulate trims installed in wood doors and is factory: Supplied recessed into the door face, to provide a neat f...
Flush Mounted Steel Trim for Insulated glass – Designed for 1” thick insulated glass. Recessed into the surface of the door face Accommodates 1" (25 mm) thick glass. When installed, fastener...
Overlapping Steel Trim (also refer to as conventional steel trim) – This trim is the typical glass trim supplied by most hollow metal manufacturers. Surface mounted on the door face. Accommo...
Flush Mounted Steel Trim – This trim is similar to Overlapping Steel Trim but is factory supplied recessed into the door face and is available for 1/4” glass. Glazing stops are screw attached, fast...
 Basic glass trim details:
Types of astragal offered from Steelcraft are as follows: "Z" Astragal - For information on "Z" astragal types and attachment refer to the TD Manual page 3.3.17. Most commonly used on double ...
Glass Light is a preparation in a door for view window, vision and/or glazing including glass stop and glazing bead and may also be refereed to as a lite. Doors are available with a wide variety o...
On May 1, 2013 the LM9000 lock series was discontinued and replaced with the LM9300 Multipoint Lock series. See related solution for information on current multipoint offering: What is th...
The Schlage LM9000 Multipoint Solution was a three-point locking assembly that was UL approved to FEMA 361 and FEMA 320 guidelines for outswing doors, and met ANSI ICC 500 for tornad...
Hinge manufacturers do not require or recommend that doors should be reinforced for continuous hinges. Steelcraft does not reinforce for continuous hinges unless it is specified on the customers' P...
Maximum Dutch Door sizes are: Non Labeled = 4'0" wide X 8'0" High Labeled = 4'0" wide X 7'2" High Special sized Dutch Doors are available: Special size top and/or bottom leaves are availabl...
Yes, glass light can be used or prepped in conjunction with the Von Duprin 94/95 Series INPACT device however there are dimensional limitations between the glass light and the InPact door preparati...
Glass lights available: Standard Glass Lights - The N4, N5 & V lite can be used at standard locations with out any modification. Glass Light Options - Other glass lights are available but ...
Steelcraft offers all the standard lights as well as special size glass lights in the H-series door. Effective April 1, 2012, (Bulletin # B-100.12) the default for Dezigner Trim in H-Series Doors...
Hinge Spacing: All 4 1/2" and 5" butt hinge spacing 1. Opening heights 3'0" through 4'11 15/16" (one pair butt hinges) from under head CL 9 3/4" (top of door 9 5/8") from bottom of frame ...
Hinge Backset: On the frame = 5/16" On the door = 1/4"
Lock Spacing: All standard bored locks ANSI 115.2 (161, 61L type), for mortise lock ANSI 115.1 (86 type) all locations must be altered 3/8" lower, and standard strike (ASA type). 1. Opening ...
Blast and pressure resistant doors protect people and property from explosions and shrapnel. More damage is generally caused by shrapnel than the blast itself, and a properly specified and engineer...
Steelcraft Blast Resistant Assemblies meet the following Blast Test Standards:                    ...
The SL-Series door is a square edge non-handed door. A Hinge Filler  (also referred to as Hinge Spacer) is the small removable trim part located on the door between hinge leaf and hinge reinforcem...
Yes, Steelcraft does offer optional A60 and A40 Galvannealed, and G90 Galvanized steel on doors and frames. Galvannealed A60 and A40: A60 coating designation - optional on all doors and frame...