Allegion
Terms of Use
Privacy Policy
Frequently Asked Questions
Ask your question
Entering your question as a complete sentence will provide more accurate results than keywords or phrases.
User questions
FAQs
Category List
“
steelcraft door edge guard
”
RELATED FAQS
Question
Answer
What are the standard door and frame clearances?
Resolution:
To determine Actual Door Size, the following values are subtracted from nominal door size (frame opening/order size) Actual Door Size: The largest measured width by height of the door leaf as m...:
What is the difference between the Ives 482B and the 482A door guards?
Resolution:
The difference between the Brass version 482B and the Aluminum version 482A is the size and design as well as the base material and available accessories. The Brass version 482B comes w...:
Are H-Series doors available with seamless edges?
Resolution:
For hurricane applications, seamless edges are available as an option:H-Series doors are available with optional seamed filled (HF) seam welded (HW) door edges.HE-Series doors are availab...:
Does the SL-Series door have a square edge?
Resolution:
The SL-Series door is a square edge non-handed door. A Hinge Filler (also referred to as Hinge Spacer) is the small removable trim part located on the door between hinge leaf and hinge reinforcem...:
Does Steelcraft offer seamless edge door?
Resolution:
Steelcraft does offer two types of seamless edge construction that support SDI classification standard Model 2 -seamless. Filled Edge: Epoxy fill, two part epoxy filled and dressed smooth. (LF, ...:
Does the Ives 482 Door Guard come with a rub plate?
Resolution:
The Ives 482 does not come with a rub plate. The brass 482 Door guard (also called 482B) comes with an edge guard or plate that is applied with adhesive to protect the edge of the door.T...:
Can the 2670 be cut down to fit smaller door widths?
Resolution:
The 2670 Guard X device can't be cut down to fit doors less than 3 feet. This device is designed to fit doors 36"- 48" in door width.:
What strike is required when using the 2670 Guard-X on a pair of doors?
Resolution:
With a mullion: Use the standard strike 267 With no mullion and inactive leaf being held closed with flush or surface bolts: Use the 2609 double door strike :
Is the Von Duprin Guard-X exit device fire rated?
Resolution:
The Von Duprin Guard-X exit device is not fire rated because the deadbolt is not spring loaded. Therefore, there would be no positive latching as required on a fire rated opening. :
Are steel stiffeners required in all door constructions?
Resolution:
No, steel stiffeners are not required in Hollow Metal doors, they are one of many optional core available.Per ANSI/SDI A250.8 and ANSI/HMMA 867, core construction are optional offeri...: