SS signal switch installation

RELATED FAQS

Question
Answer
When the "RED" LED on the 8310-865 RF Receiver is blinking, it is receiving an RF signal (interference) from a non programmed device. When receiving this type of signal, it will not program correct...
You must replace the entire RX switch assembly for Chexit devices shipped after 8-24-2015 with motor driven.
The part number for the RX switch pig tail (black plug) with two orange wires only for Chexit devices shipped prior to 8-24-2015 with solenoid driven is 991338-00. 
The Request for Exit (RX) is available on the 55 and 88 Series Von Duprin devices.The RX switch is installed in the end case of 55 and 88 series exit devices.There is no kit to field install the RX...
The devices baseplates/scissor assemblies are different and will not accept the Von Duprin RX switch.
Storeroom Lock with Request to Exit - The Outside Lever is same as ND80 - The Inside Lever is the same as ND80- A microswitch attached to the chassis is activated when the lever is rotated. The sw...
The RX monitors the push bar while the LX monitors the latch bolt of the exit device. A SS device has an LX and a key cylinder switch plus an emergency push bar signage.
SS, LX, RX
The signal switch(S) will automatically be installed in an EL1490 and EL1590 devices when built at factory. Red, Green, and Black are the wires to the switch and are shown in the 1490 instructio...
DS
SS
The SUS can change the logic polarity of the AD400/WRI400 PIM400-TD2 outputs RTX, DPS, TROUBLE, and REN from LOCK/DOOR PROPERTIES Edit tab. You can change High to Low to High using the ed...
  These SUS settings have no effect when the AD400 is linked to a PIM400-485; because the PIM400-485 reports the logic status with RSI-485 commands and not logic levels. The settings are gray...
Depends on what is being ordered; SS can stand for either the "Signal Switch" or the "Silk Screen" push bar. The SS (Signal Switch) and ALK (Exit Alarm) sit in the same location in the exit devi...
The attached table shows the part numbers for LX-RX and LX-RX-LC switches field installed.
On August 15, 2012 Schlage began shipping ND-Series locks with a hassle free clip to aid with the installation of the anti-rotation plate.  This feature has been added to the hub to keep the anti-r...
The ND lock is available with an RX option:When ordering a complete ND lock specify RX when the request to exit (RX) switch is required.The ND80EL, ND80EU, ND96EL, ND96EU, ND12EL, ND12EU electrifie...
To keep the Von Duprin electric latch retraction EL or QELA exit device dogged (retracted) all day, have your access control, Key pad, key switch, fire alarm contact or any other signals ...
The RX switch is required to activate the ALK. The RX switch monitors the pushbar and will signal the ALK to go into alarm when the pushbar is depressed. The RX switch also allows free in...