RX with mag
”
RELATED FAQS
Question
Answer
GF3000 coil does not float
Resolution:
Current production GF3000 have a fixed , solid coil. Previous models excluding the BRD had spring load floating coils. This allowed the coil to drop and meet the armature, Engineering is reviewing ...:
Can the CD cylinder dogging and RX switch be ordered with 33/35 or 98/99 exit device?
Resolution:
This can be done ONLY with non fire rated exit devices.:
Can a pneumatic (PN) 33A/35A/98/99 exit device use the RX or LX switches?
Resolution:
PN33/35/98/99 Pneumatic exit devices are not usually used with RX or LX switches since the Pneumatic PN device is used instead EL to eliminate the electric from the device.:
Can the 94/9547 have the RX option?
Resolution:
The RX request exit switch is not available with 94/95 exit devices.:
Is the MA lock available with the RX feature?
Resolution:
The MA RX features a single switch within the chassis that will monitor both the inside and outside knob/lever. The switch is only available as Normally Open (NO).:
Does the Falcon T series have an RX option available?
Resolution:
The Falcon T Series lock does not have an RX switch available.:
Does the ND lock have an RX option?
Resolution:
The ND lock is available with an RX option: When ordering a complete ND lock specify RX when the request to exit (RX) switch is required. The ND80EL, ND80EU, ND96EL, ND96EU, ND12EL, ND12E...:
Maglock Making a "Buzzing" Noise
Resolution:
:
Does a Von Duprin ALK kit come with an RX switch?
Resolution:
ALK kit comes with standard RX switch. It can be ordered without the RX switch or with LX switch as an option.:
What power supply is used with RX or LX switches?
Resolution:
The RX switch is request exit and the LX switch is latch bolt monitor switch. They do not require a power supply directly. The electrified hardware that the RX or LX switch...:
Will Von Duprin supply the 996L, 996L-BE, 996L-NL and 996L-DT trims with an RX switch?
Resolution:
Von duprin will supply the 996L and 996L-BE trims with RX switch. Von Duprin will not supply the 996L-NL and 996L-DT trims with RX switch because the switch monitors the lever movement and the leve...:
What is (SD) Special Dogging?
Resolution:
SD is Special cylinder dogging in the center case of 98/99 rim and vertical rod non fire rated devices and is available with standard, EL, QEL, CX and ALK.:
What is the L9080 by L283-263?
Resolution:
L283-263 and L283-239 are obsolete part numbers that were used to specify "request to exit" on the L9000 and LV9000 locks. To specify RX on L9000 locks after January 2, 2017, specify the lette...:
When did we Von Duprin release the RX996L trim as a standard?
Resolution:
The Von Duprin RX996L trim was released to standard order entry in May 2010. The Von Duprin 996L and 996L-BE trims can be ordered with RX switch. The 996L-NL and 996L-DT trims can not have the...:
Does the M490DE come with a delayed egress warning sign?
Resolution:
A delayed egress sign is provided with the M490DE and the M490DEP. The sign's part number is P774358:
Can a Von Duprin delay egress controller DE5101 run a pair of doors?
Resolution:
One Delayed Egress Controller (DE5101) can run two mag locks on a pair of doors, provided the doors are not controlled independently:
Can we run both mag locks and EL devices from the PS 914?
Resolution:
It requires 900-4RL and 900-FA option boards to release the mag locks when a fire alarm is activated. Specify PS914 x 900-4RL x 900-FA.:
Magnetic Stripe Card Coersivity
Resolution:
Magstripes come in two main varieties: high-coercivity (HiCo) at 4000 Oe and low-coercivity (LoCo) at 300 Oe but it is not infrequent to have intermediate values at 2750 Oe. High-coercivity magstri...:
Does Von Duprin still sell mag locks?
Resolution:
Von Duprin discontinued selling mag locks in the early 1990's.:
What is a locknetics 268/24-10 dual mag functionally equivalent to?
Resolution:
Functionally equivalent to a schlage 350+ which is functionally equivalent to a M450:
Will mag locks operate with voltage ranges between 12vdc and 24vdc?
Resolution:
The entire series of mag locks that Schlage provides advertises 12vdc or 24vdc because they will automatically determine what voltage is being used and switch the internal circuitry based on that v...:
Why is my mag lock buzzing?
Resolution:
Rattling could be caused by improper mounting of the mounting plate or armature. Make sure all components are properly secured.:
Will a PS902 power my mag lock and my DE5101?
Resolution:
This is possible as long as the total current draw does not exceed the 2 amp capacity of the PS902 power supply. The Schlage Electronics 320, 350, or 390 maglock must be used with a DE5101 and th...: