rough opening knock down frame

RELATED FAQS

Question
Answer
The rough opening dimensions are the same for either Welded (SUA) or Knock Down (KD) frames For F, FN, FE, DE, MU three sided frames and four sided borrowed light frames: New masonry W...
 For DW, K three sided frames and four sided borrowed light frames: Three sided frame = door opening width (order size) plus 1 1/2" minimum to 2" maximum and the door opening hei...
POCKET DOOR FRAME: A frame designed to allow a door to slide inside a pocket located within the cavity of a wall. The hinge jamb of the frame is replaced with a 2 piece jamb without a stop. I...
Knock Down (KD) frames: KD frames are designed, manufactured and supplied with integral miters which include all notches, interlocking corner tabs and slots to allow for field assembly and do not r...
Side Light and Side Panel frames - Side Light and Side Panel frames are not KD (Knock Down), they must be assembled and welded. All side lite and side panel frames must be assembled and welde...
Cabinet Jamb
Frame Installation Clearance
A Double Egress frame is a double door frame prepared to receive two single-acting doors swinging in opposite directions (both doors are) the same hand. These openings are installed in cross corrid...
For compression anchor details refer to the “ANCHORING SYSTEMS”  section in the Steelcraft Tech Data Manual.
From head to centerline of each hinge (4 1/2" or 5") is 9 3/4", 39 3/64", 68 11/32" & 97 41/64".
The hinge spacing on a 9'0" frame opening height is 29 19/64".
From Head to top of each 4 1/2" hinge is 7 1/2", 36 51/64", 66 3/32" & 95 25/64". From Head to top of each 5" hinge is 7 1/4", 36 35/64", 65 27/32" & 95 9/64".
DW/K-Series frames (Drywall Slip-On) are not recommended for installation in high traffic areas. DW/K-Series frames are installed in interior stud walls after the wall board is installed and ...